900276 -
SERVICING THE ECCENTRIC BEARING (see Fig. 4)
NOTE: For model 6602 only, Model 6604 does not require this service.
Once every three months, depending upon usage, remove the shear head from the power unit following the A instructions in the REPLACING CUTTERS section of the manual.
CAUTION: DISCONNECT TOOL
FROM POWER SOURCE BEFORE DISASSEMBLING.
Put a few drops of heavy oil on the
eccentric bearing assembly (A) Fig. 4,Fig. 4
so that it saturates the needle bearing. The outside surface of the eccentric bearing ring and the yoke of the center blade should be coated with bearing lubricant.
SERVICE AND REPAIRS
All quality tools will eventually require servicing or replacement of parts due to wear from normal use. These operations, including brush inspection and replacement, should ONLY be performed by either an AUTHORIZED
Should you have any questions about your tool, feel free to write us at any time. In any communications, please give all information shown on the nameplate of your tool (model number, type, serial number, etc.).
ACCESSORIES
A complete line of accessories is available from your
WARNING: Since accessories other than those offered by
•Delta have not been tested with this product, use of such accessories could be hazardous. For safest operation, only
9