901891 -
TROUBLESHOOTING
WARNING: Disconnect tool from air supply and/or remove battery before performing any Service Procedure.
|
| SYMPTOM | PROBLEMS | SOLUTIONS |
|
| 1. | Air leak near top of | Loose screws. | Tighten screws. |
|
|
| tool or in trigger area. | Worn or damaged | Install Overhaul Kit. |
|
|
|
|
|
| |
|
|
|
|
|
|
| 2. | Tool does nothing or | Inadequate air supply. | Verify adequate air supply. |
|
|
| operates sluggishly. | Inadequate lubrication. | Rotate air inlet to 12:00 position |
|
|
|
|
| and add |
|
|
|
| Worn or damaged | Install Overhaul Kit. |
|
|
|
|
|
| |
|
|
|
|
|
|
| 3. | Air leak near bottom | Loose screws. | Tighten screws. |
|
|
| of tool. | Worn or damaged | Install Overhaul Kit. |
|
|
|
|
|
| |
|
|
|
|
|
|
| 4. | Tool jams frequently. | Incorrect fasteners. | Verify approved fasteners of |
|
|
|
|
| correct size. |
|
|
|
| Damaged fasteners. | Replace w/undamaged fasteners. |
|
|
|
| Magazine or nose | Tighten screws. |
|
|
|
| screws loose. |
|
|
|
|
| Magazine is dirty. | Clean magazine. |
|
|
|
| Driver is worn or damaged. | Install Driver Maintenance Kit. |
|
|
|
|
|
|
|
| 5. | Insufficient nails per | Switch set to high position. | Use normal setting to maximize |
|
|
| battery charge. |
| efficiency of tool. |
|
|
|
|
|
|
|
| 6. | Compressor runs | Quick connect valve open. | Rotate quick connect valve to the |
|
|
| continuously and red |
| 8:00 “closed” position. |
|
|
| LED flashes rapidly. |
|
|
|
|
|
|
|
|
|
| 7. | Compressor does not | Automatic shutdown feature | Turn compressor off and back on |
|
|
| run and red LED | activated because tool was | to reset controls. |
|
|
| flashes slowly. | idle for two hours. |
|
|
|
|
|
|
|
|
| 8. | Compressor does not | Battery voltage to low | Recharge or replace battery. |
|
|
| run and red LED is on. | “discharged”. |
|
|
|
|
|
|
|
|
| 9. | Other |
| Contact a |
|
|
|
|
| Service Facility. |
|
16