Porter-Cable C7510 instruction manual Before Each Start-Up, How to Start

Models: C7510

1 28
Download 28 pages 16.91 Kb
Page 15
Image 15

Before Each Start-Up:

1.Place On/Auto/Off lever to “OFF”.

2.Close the globe valve.

3.Attach hose and accessories. NOTE: A regulator MUST be installed when using accessories rated at less than 110 PSI.

Too much air pressure causes a hazardous risk of bursting. Check the manufacturer’s maximum pressure rating for air

tools and accessories. The regulator outlet pressure must never exceed the maximum pressure rating.

How to Start

1.Turn the On/Auto/Off lever to “AUTO” and allow tank pressure to build. Motor will stop when tank pressure reaches “cut-out” pressure.

2.When the tank pressure reaches “cut-out” pressure open the globe valve.

IMPORTANT: When using regulator and other accessories refer to the manufacturers instructions.

NOTE: Always operate the air compressor in well-ventilated areas free of gasoline or other combustible vapors. If the compressor is being used to operate a sprayer, DO NOT place compressor near the spray area.

15- ENG

D28176

Page 15
Image 15
Porter-Cable C7510 instruction manual Before Each Start-Up, How to Start