GLOSSARY

Become familiar with these terms before operating the unit. CFM: Cubic feet per minute.

SCFM: Standard cubic feet per minute; a unit of measure of air delivery.

PSIG: Pounds per square inch gauge; a unit of measure of pressure.

Code Certification: Products that bear one or more of the following marks: UL, CUL, ETL, CETL, have been evaluated by OSHA certified independent safety laboratories and meet the applicable Underwriters Laboratories Standards for Safety.

Cut-In Pressure: While the motor is off, air tank pressure drops as you continue to use your accessory. When the tank pressure drops to a certain low level the motor will restart automatically. The low pressure at which the motor automatically restarts is called “cut-in” pressure.

Cut-Out Pressure: When an air compressor is turned on and begins to run, air pressure in the air tank begins to build. It builds to a certain high pressure before the motor automatically shuts off - protecting your air tank from pressure higher than its capacity. The high pressure at which the motor shuts off is called “cut-out” pressure.

Branch Circuit: Circuit carrying electricity from electrical panel to outlet.

DUTY CYCLE

This air compressor pump is capable of running continuously. To prolong the life of the air compressor run it at a 50% - 75% duty cycle (air compressor pumping time is 30-45 minutes per hour).

SPECIFICATIONS

 

Model No.

C7510

 

Horsepower Peak

7.0

*

Voltage-Single Phase

240V

* *

Minimum Branch Circuit Requirement

15 amps

*

Fuse Type

Time Delay

 

Air Tank Capacity (Gallon)

60

 

Approximate Cut-in Pressure

110 PSIG

 

Approximate Cut-out Pressure

135 PSIG

 

SCFM @ 40 PSIG

12.3

 

SCFM @ 90 PSIG

10.4

* This air compressor can be operated on a 15 amp circuit if:

1.Voltage supply to circuit is normal.

2.Circuit is not used to supply any other electrical needs (lights, appliances, etc.)

3.Extension cords comply with specifications in owners manual.

4.Circuit is equipped with 15 amp circuit breaker or 15 amp time delay fuse.

If any of the above conditions cannot be met, or if operation of the air compressor repeatedly causes interruption of the power it may be necessary to operate it from a 20 amp circuit. It is not necessary to change the cord set.

** A circuit breaker is preferred. Use only a fuse or circuit breaker that is the same rating as the branch circuit on which the air compressor is operated. If the air compressor is connected to a circuit protected by fuses, use dual element time delay fuses.

D28176

8- ENG

Page 8