PROBLEM

CAUSE

CORRECTION

Pressure reading on the regulated pressure gauge (if equipped) drops when an accessory is used.

It is normal for "some" pressure drop to occur.

If there is an excessive amount of pressure drop when the accessory is used, adjust the regulator as instructed in the Operation section.

NOTE: Adjust the regulated pressure under flow conditions (while accesory is being used).

Air leak from

Possible defect in safety

Operate safety valve manually

safety valve.

valve.

by pulling on ring. If valve still

 

 

leaks, it should be replaced.

Compressor is

Prolonged excessive use of

not supplying

air.

enough air to

Compressor is not large

operate

enough for air requirement.

accessories.

 

 

Hole in hose.

 

Check valve restricted.

 

Air leaks.

 

Restricted air intake filter.

Loose belt.

Decrease amount of air usage.

Check the accessory air requirement. If it is higher than the SCFM or pressure supplied by your air compressor, you need a larger compressor. Check and replace if required.

Remove and clean, or replace.

Tighten fittings.

Clean or replace air intake filter. Do not operate the air compressor with the filter removed. Refer to the "Air Filter" paragraph in the "Maintenance " section.

Check belt tension, see Adjusting Belt Tension in the Maintenance section.

Restricted air

Dirty air filter.

Clean or replace. See Air Filter

intake.

 

paragraph in the Maintenance

 

 

section.

 

 

 

D28176

24- ENG

Page 24
Image 24
Porter-Cable C7510 instruction manual Prolonged excessive use