If the nozzle becomes clogged with foreign materials, such as dirt, excessive pressure may develop. If the nozzle becomes partially clogged or restricted, the pump pressure will pulsate. Clean the nozzle immediately using the nozzle kit supplied and the following instructions:

1.Shut off the pressure washer and turn off the water supply.

2.Disconnect spark plug wire.

3.Pull trigger on gun handle to relieve any water pressure.

4.Disconnect the wand from the gun.

5.Remove the high-pressure nozzle from the wand. Remove any obstructions with the nozzle cleaning tool provided and backflush with clean water.

6.Direct water supply into nozzle end to backflush loosened particles for 30 seconds.

7.Reassemble the nozzle to the wand.

8.Reconnect wand to gun and turn on water supply.

9.Start pressure washer and place wand into high pressure setting to test.

HOW TO CLEAN THE WATER INLET FILTER

This screen filter should be checked periodically and cleaned if necessary.

1.Remove filter by grasping end and removing it from water inlet of pump as shown.

2.Clean filter by flushing it with water on both sides.

3.Re-insert filter into water inlet of pump.

Filter Screen

D25805

14- ENG