Porter-Cable D26729-028-0 instruction manual To Start The Engine, Stopping Engine

Models: D26729-028-0

1 22
Download 22 pages 14.94 Kb
Page 12
Image 12
TO START THE ENGINE

Engine speed has been factory set to provide safe operation. Tampering with the engine speed adjustment could result in over-

heating of attachments and could cause a fire. Never attempt to “speed-up” the en- gine to obtain more performance. Both the output voltage and frequency will be thrown out of standard by this practice, endangering attachments and the user.

You MUST unplug any load from the generator before starting to prevent permanent damage to any appliances.

TO START THE ENGINE

Never run engine indoors or in enclosed, poor ventilated areas, engine exhaust contains carbon monoxide, an odorless and deadly gas.

1.On the engine there is a ON/OFF switch located on the front panel of the engine. Place this switch to the "ON" position

2.Push primer button three times. Wait two seconds between each push. In cold weather (50ºF/10ºC or below) push five times.

NOTE: Primer may be needed to restart a warm engine after a short shutdown.

3.Grasp handle on rope starter and pull slowly until resistance is felt. Let the rope rewind slowly. Pull rope with a rapid full arm stroke. Let rope rewind slowly. Repeat if necessary.

IMPORTANT: Allow generator to run at no load for 5 minutes upon each initial start-up to allow engine and generator to stabilize.

STOPPING ENGINE

1.Disconnect all electrical loads.

2.Turn ON/OFF switch to "OFF" position.

D26729

12- ENG

Page 12
Image 12
Porter-Cable D26729-028-0 instruction manual To Start The Engine, Stopping Engine