ASSEMBLY
Read this manual. Do not attempt to operate equipment until you have read this Manual for Safety, Operation, and
Maintenance Instructions.
NOTE: This manual is a general manual. Information in this manual may or may not pertain to your model. Please read carefully.
NOTE: Left and right describes the location of a part with the operator facing the outlet panel.
REMOVE GENERATOR FROM CARTON
•Open carton from top.
•Cut carton along dotted lines.
•Remove all carton inserts.
•Remove generator through opening in carton.
•Remove shipping shims.
a.Locate shipping shims (a) under generator frame.
b.Loosen but do not remove limiter bolts (b).
c.Pull label (c) and remove shims.
d.Retighten limiter bolts. Torque to
It is very important that these are removed before starting your generator.
ac
b
b
c
OTHER LOOSE PARTS
1.Oil is supplied, see engine operators manual for correct procedure to add oil and fuel to engine.
IMPORTANT: Before any attempt to start your generator be sure to check engine oil (See Engine Operator's manual)
GROUNDING THE GENERATOR
A grounding lug is supplied with the generator for use when required by local electrical ordinances. Refer to article 250 of the National Electrical Code to clarify any needed grounding information. Your local electric company or a certified electrician should be able to help you with this information.
Grounding Lug
9- ENG | D26729 |