Porter-Cable FRP350 instruction manual Clearing a Jammed Fastener

Models: FRP350

1 15
Download 15 pages 35.05 Kb
Page 11
Image 11

CLEARING A JAMMED FASTENER

Disconnect tool from air supply.

1.Remove any remaining fasteners from the nailer.

A.Place finger in recess (A) Fig. 28, and depress lever to release follower mechanism.

B.With follower release lever depressed (A) Fig. 28, slide follower all the way to the front of the magazine.

C.Depress spring (B) Fig. 29, slide fasteners to the rear, and remove all fasteners from magazine (see Fig. 19).

2.Use a pair of needle nose pliers and/or a flat screwdriver to free bent fastener from back of nosepiece. If fastener cannot be removed as described, it may be necessary to remove the magazine as follows:

A.Loosen knob (A) Fig. 30 and move magazine in slotted bracket (B).

B.Slide magazine back, off of nosepiece. See (B) Fig. 31.

C.After clearing bent fastener (A) Fig. 31, reverse above steps to reassemble.

A

Fig. 28

Fig. 30

A

B

Fig. 29

B

B

AFig. 31

11

Page 11
Image 11
Porter-Cable FRP350 instruction manual Clearing a Jammed Fastener