Console Cover

Gauges

Safety

Quick

Valve Regulator Manifold

Connect

5.Remove the hose by removing the hose clamp. NOTE: The hose clamp is not reusable. You must purchase a new hose clamp, see Replacement Parts in the Service section or purchase a standard hose clamp at a local hardware store.

6.Remove pump mounting screws securing pump (one on each side).

Pump Mounting Screw

Hose

Clamp

7.Carefully slide pump from brackets and out of the way.

8.Using an adjustable wrench remove the regulator manifold.

9.Apply pipe sealant to new regulator manifold and assemble, tighten with wrench.

10.Reapply pipe sealant to gauges, quick connect, and safety valve.

Pump

shown moved out of the way

Regulator

Manifold

11. Reassemble all components in reverse order of removal. Make sure to orient gauges to read correctly and use wrenches to tighten all components.

STORAGE

Before you store the air compressor, make sure you do the following:

1.Review the Maintenance section on the preceding pages and perform scheduled maintenance as necessary.

2.Drain water from air tank. See To Drain Tank under Maintenance.

Water will condense in the air tank. If not drained, water will corrode and weaken the air tank causing a risk of air tank rupture.

3.Protect the electrical cord and air hose from damage (such as being stepped on or run over). Wind them loosely around the compressor handle.

4.Store the air compressor in a clean and dry location.

14 - ENG

Page 14
Image 14
Porter-Cable N039112 instruction manual Storage, Pump Shown moved out of the way Regulator Manifold