PROBLEM | CAUSE | CORRECTION |
|
|
|
Motor will not run. | Fuse blown, circuit | Check fuse box |
| breaker tripped. | for blown fuse and |
|
| replace as necessary. |
|
| Reset circuit breaker. |
|
| Do not use a fuse or |
|
| circuit breaker with |
|
| higher rating than |
|
| that specified for your |
|
| particular branch circuit. |
|
| Check for proper |
|
| fuse. You should use |
|
| a time delay fuse. |
|
| Check for low |
|
| voltage problem. |
|
| Check the |
|
| extension cord. |
|
| Disconnect the other |
|
| electrical appliances |
|
| from circuit or operate |
|
| the compressor on its |
|
| own branch circuit. |
|
|
|
| Extension cord is wrong | Check the |
| length or gauge. | extension cord. |
|
|
|
| Loose electrical | Check wiring connection |
| connections. | inside terminal box. |
|
|
|
| Faulty motor. | Have checked by |
|
| a Trained Service |
|
| Technician. |
|
|
|
Motor will not run. | Motor overload | Refer to Motor |
| protection switch | Overload Protection |
| has tripped | under Operation. |
|
| If motor overload |
|
| protection trips |
|
| frequently, contact |
|
| a Trained Service |
|
| Technician |
|
|
|