￿Compensation – This list button selects the distance to advance the mouse toward edge from touch point.

d.USB touch right button tool

This tool differs slightly from the “Touch as Right Button Click” check box in the USB touch manager. When executed, there will be a small window of “One Shot Right Button” appearing on desktop. Any touch on the panel right after touching this small window will work like clicking the right button of mouse at that point. However, the next touch will resume the left button of mouse unless the small window is touched again.

C.APPLICATION LIMITATION

The USB touch is not applicable for OS other than Windows as USB mouse is not supported in DOS environment and there is difficulty in engaging driver to convert the coordination system between the static panel and the dynamic mouse in Linux environment. The USB touch is also not applicable when the monitor is used to be the extended screen in multiple monitor application.

In using the MSR of the side mounted upgrade option for reading a magnetic stripe card, be sure to insert the card to the bottom with magnetic stripe facing the mark aside the slot. The movement of the card can be either inserting the card from the top surface then sliding the card down out of the slot, or sliding the card upward from the lower side of the slot till it reaches the top end as long as the card is a standard one. A non-standard card recorded without complete degaussing prior to recovery may accept only one direction in card reading.

If the fingerprint sensor option is installed in the side mount kit, please find the most comfortable angle for the fingerprint taking operation in consideration of the LCD panel tilt angle and try to align the core of fingerprint in the sensing area.

VIII. LED MODULE INDICATION

Green: standby

Blue: power on

When this touch monitor is turned ON and the LED lights in blue. When the VGA signal vanishes, the monitor shows “No signal” for a while and goes into standby mode and LED is green. However, the touch panel is still operational.

Part 7

Page 7
Image 7
POSIFLEX Business Machines LM-/TM-7115/7115N user manual VIII. LED Module Indication, USB touch right button tool