Powercom 425AP, 525AP, 625AP, 325A user manual Storage, Specifications

Models: 525AP 425AP 625AP 525A 625A 425A 325A

1 17
Download 17 pages 49.9 Kb
Page 16
Image 16

11.Storage

__________________________________________________________

____

10.1 Storage conditions

Store the UPS covered and upright in a cool , dry location, with its battery fully charged. Before storing, charger the UPS for at least 4 hours. Remove any accessories in the accessory slot and disconnect any cables connected to the computer interface port to avoid unnecessary draining the battery.

10.2 Extended storage

During extended storage in environments where the ambient temperature is -15 to +30 (+5 to +86 ), charge the UPS‘s battery every 6 months.

During extended storage in environments where the ambient temperature is +30 to +45 (+86 to +113 ), charge the UPS‘s battery every 3 months.

12.Specifications

__________________________________________________________

____

MODEL

 

325A

 

425A(P)

525A(P)

 

625A(P)

INPUT

Capacity

325VA

 

425VA

525VA

 

625VA

 

Voltage

100V, 110V, 120V, 220V, 232V, 240V, +/-25%

 

Frequency

 

 

50 or 60Hz +/-5% (auto sensing)

 

OUTPUT

Voltage

 

Simulated sine wave at Line Input +/-5%

 

 

(on battery)

 

 

 

 

 

 

 

Frequency

 

 

50 or 60Hz +/-0.5%

 

 

(on battery)

 

 

 

 

 

 

 

Voltage

AVR automatically increase output voltage 15% above input

 

Regulation

voltage if -9% to-25% of nominal. AVR decrease output voltage

 

AVR

13% below input voltage if+9% to 25% of nominal

 

 

 

 

 

 

Transfer Time

 

2/4 milliseconds, including detection time

 

PROTECTION

Spike Protection

 

 

320 joules, 2ms

 

and

 

 

 

 

 

 

 

FILTERING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EMI/RFI filter

 

 

10dB at15MHz, 50dB at 30MHz

 

 

 

 

 

(for xxxAP models only)

 

 

Overload

UPS automatic shutdown if overload exceeds 110% of nominal at

 

Protection

 

 

60 second and 130% at 3 seconds.

 

 

Unit Input

 

Fuse for overload & short circuit protection

 

 

 

 

 

 

 

10Baase-T

 

 

Network (UTP, RJ-45) compatible jacks

 

 

Cable Port

 

 

(for xxxAp models only)

 

 

Short Circuit

UPS output cut off immediately or input fuse protection

BATTERY

Type

 

 

Sealed, maintenance-free lead acid

 

Page 16
Image 16