STATUS INDICATORS

Status indicator LED’s relay conditions of generator function for user or service technician convenience. Illumination of these indicator LED’s communicate conditions that require generator service but are not severe enough to cause damage if the generator is allowed to operate. Contact a qualified service technician immediately for service if any of the listed LED’s are lit, even if the generator appears to function normally.

LOW BATTERY

The Low Battery LED is will illuminate Red when the cranking battery voltage falls below 11.0 volts. At this level, the battery begins to lose the ability to consistently start the engine. Causes of low battery voltage may include a failing battery, failed battery charger or failed engine alternator.

ENGINE RUN

The Engine Run LED illuminates Green when the generators engine is running. This is the only light lit when the generator is supplying power as intended.

FAULTS

Fault lights relay conditions that may cause damage to the generator and/or loads connected to the output of the generator. When any of the listed situations occur while the generator is running, the generator is shut down and the fault light associated with the shutdown cause is lit. Once the light is lit, it remains on until it is cleared by pressing the OFF button on the control panel. If a fault light is lit, determine and correct the cause of the problem before restarting the generator. During generator starting, the controller ignores fault conditions until 15 seconds after the generator starts, then uncleared faults will once again cause the generator to shut off. To determine possible fault causes, refer to the troubleshooting section of this manual or contact a qualified service technician for assistance.

HIGH TEMPERATURE

The High Temperature LED illuminates Red if the temperature of the engine becomes too high. Engine oil temperature is monitored while the engine is active and the engine is shut off to avoid damage if the oil temperature becomes too high. When operating the generator in temperatures above the maximum listed on the nameplate, it is necessary to reduce the load connected to the generator to avoid overheating. If high ambient temperatures or excessive loads are eliminated as possible causes of High Temperature shutdown, check to insure cabinet openings are not restricted by debris.

LOW OIL

The Low Oil LED illuminates Red and the engine is shut off if the engine oil pressure falls

too low. To avoid engine damage, engine oil pressure is monitored to determine the amount of oil in the engine. When pressure falls below a preset level, a Low Oil fault occurs. Check for proper oil level if the generator shuts down due to a Low Oil alarm.

OVERCRANK

The Overcrank LED is illuminated Red if all three 10 second cyclic crank attempts are unsuccessful in starting the engine. Once the light is on, the generator does not attempt to start until the fault is reset. When the Overcrank LED is lit, verify fuel is available at the inlet to the unit, then check the condition of the cranking battery.

OVERSPEED

The Overspeed LED is illuminated Red if the generator engine is running too fast. Electrical output of the generator at high speeds may damage loads connected to the generator output and/or engine failure may occur at excessive speeds. If the generator shuts down on an Overspeed error, seek assistance from a qualified generator service technician.

LOSS SPEED

The Loss Speed LED is illuminated Red if the generator engine is running too slow. Electrical output of the generator at low speeds can damage loads connected to the generator output and/or generator failure may occur due to excessive heating in the generator head. If the generator turns off due to an Loss Speed error, check to see that the connected loads do not exceed the nameplate rating of the generator.

AUX 1

This is a common alarm, it flashes when there is a failure or alarm. A signal is sent to the transfer switch and illuminates the generator failure LED located on the transfer switch.