TROUBLESHOOTING
SYMPTOM | POSSIBLE CAUSE | CORRECTIVE ACTION | |
|
|
| |
Low generator output | Excitation capacitor failure | • Contact a qualified generator dealer for service assistance. | |
|
| ||
voltage | Generator diode or varistor | • Contact a qualified generator dealer for service assistance. | |
| failure | ||
|
| ||
Overspeed LED stays lit | Shutdown due to high engine | • Verify correct engine speed setting. | |
speed | |||
Low Speed LED stays lit | Shutdown due to low engine | • Reduce loads connected to generator. | |
speed | |||
Overcrank light stays lit | Failure to start | • See "Engine cranks without starting". | |
|
|
| |
Low oil pressure LED | Shutdown due to low engine | • Check engine oil level. | |
| |||
stays lit | oil pressure | • Verify correct type of engine oil for ambient temperature | |
|
| conditions. | |
|
| • Test battery. Replace as necessary. | |
|
|
| |
|
| • Ensure charger is plugged into receptacle. | |
|
|
| |
Low battery LED stays lit | Low battery | • Check for tripped main circuit breaker. Reset if required. | |
| |||
• Check all charger cable connections for cleanness and | |||
|
| ||
|
| tightness. | |
|
| • Check battery charger inline fuse. | |
|
|
| |
|
| • Check charger lights to verify correct operation. See Table | |
|
| A, Page 26. | |
|
| • Allow engine to cool, then restart. | |
High temperature LED | Shutdown due to high engine |
| |
• Decrease loads on generator. | |||
stays lit | temperature |
| |
|
| • Check enclosure openings for blockage. | |
|
|
|
29 |