Powerware P93 - Advanced Technology

The Powerware P93 offers a complete feature set to deliver the highest performance in the 20 kVA range of UPS. Whether chosen for an IT or facility environment, locally or remotely located, the Powerware P93 is the only choice to keep your business in business – around the clock.

Advanced ergonomically designed user interface panel

AEasily accessed from a standing position, panel is tilted 15 degrees for optimum viewing

ALarge LCD panel for graphic displays (4 line by 40 characters)

ALED status indicators

ASoft keys provide easy navigation through info screens

ASmart Load Off button prevents unintentional load losses

AMulti-lingual LCD panel meets global requirements

ACurrent status, history, events and alarms and an active mimic bus can be viewed

Superior cooling design

AAir filters prevent contaminants from entering the UPS

ARedundant fans provide continuous operation without derating if a fan fails

AFan failure detection and notification

ALoad-based fan speed control maximizes fan life and efficiency while minimizing audible noise and heat dissipation

AFans easily replaced while online

Easy installation

ACasters provide for easy placement of unit

AMultiple wire entry locations

ASimple installation of communication option cards

ATerminal blocks for input/output wiring

AFront covers designed with magnetic latches for effortless removal and replacement

Exceptional design for service

AFront and top access for service

ADedicated service port prevents any disturbance to the customer’s communication setup

ABattery circuit breaker

AInternal maintenance bypass switch provides isolation for safe servicing

AInput circuit breaker

ASlide out battery trays with quick disconnects

Bundled communications package

AiSeries interface port and cable (25 ft.)

AModem for 7x24 remote monitoring and Advance Response Service1

ARS-232 port (DB-9)

A(4) Building alarm inputs

A(2) Summary contacts

A(2) Unused communication slots, supports up to two different communications options

1.Requires customer provided phone line. Includes one-year ProActive Service. 2. Additional years of ProActive Service available. See Options section for details. 3. When purchased with Powerware Field Installation, PN 10300671, IBM PN 973604.

Other standard features include:

AUL 1778

AcUL CAN/CSA C22.2 No 107.1

AExceeds IEC 62040-3, UPS definition

ADouble-conversion online technology

ACold-start capability from battery

AWide input voltage and frequency window

ADual source input to rectifier and bypass

AQuiet operation, less than 60 dBA

AProActive 1 year service plan2

ATHD input filter

AInstallation3

Powerware P93

A7x24 startup

ALine up and match options cabinet containing

AExternal maintenance bypass

A42-pole distribution panel

ABranch output breakers with output distribution cables and receptacles (outlets) with various configurations to support a variety of device configurations.

ASupport dual redundant power needs of IBM devices

Page 2
Image 2
Powerware Powerware P93 Advanced Technology, Advanced ergonomically designed user interface panel, Easy installation

P93 specifications

The Powerware P93 is a reliable and efficient uninterruptible power supply (UPS) designed to provide critical backup power and ensure the protection of sensitive electronic equipment. It is particularly suitable for medium to large-scale applications such as data centers, telecommunications systems, and industrial operations. Powerware, a part of Eaton Corporation, has built a solid reputation for producing high-quality power solutions, and the P93 series exemplifies this commitment to excellence.

One of the main features of the Powerware P93 is its modular design, which allows for easy scalability and customization based on the specific power requirements of the user. This modularity means that businesses can start with a smaller unit and expand their UPS capacity as their power needs grow, thereby optimizing their initial investment.

The P93 series employs advanced double-conversion technology, providing a clean and stable output power with minimal distortion. This is crucial for protecting sensitive electronic equipment from power anomalies such as surges, sags, and outages. The UPS features a high input power factor, which not only contributes to energy efficiency but also minimizes the need for oversizing the generator capacity in backup power scenarios.

Another standout characteristic of the Powerware P93 is its energy-saving capabilities. Equipped with intelligent battery management systems, the UPS optimizes battery usage and extends their life cycle through controlled charging and discharging. Additionally, the unit supports eco-mode operation, further enhancing energy efficiency while reducing operating costs.

The P93 series also includes advanced communication and monitoring features, enabling seamless integration into existing network management systems. Users can monitor and manage the UPS via a user-friendly graphical interface, allowing for real-time insights into power conditions and performance statistics.

Moreover, the P93 is designed with redundancy and reliability in mind, featuring a hot-swappable battery design that permits maintenance without downtime. This is critical for organizations that cannot afford interruptions to their power supply. With features such as overload protection and user-replaceable components, the P93 series ensures longevity and durability.

In conclusion, the Powerware P93 provides a robust solution for organizations seeking dependable power backup. With its modular design, advanced double-conversion technology, energy-efficient features, and reliable monitoring capabilities, it is an ideal choice for safeguarding critical operations from power disturbances.