Powerware warranty Powerware P93 Specifications, Options, ProActive, X-Slot, Cabinet

Models: P93

1 6
Download 6 pages 33.74 Kb
Page 6
Image 6
Powerware P93 Specifications

Powerware P93 Specifications

 

 

 

Options

 

ProActive

X-Slot

X-Slot

X-Slot

 

 

 

 

P93

Cabinet

EBC

Service

Web/SNMP

Multi Server

Relay

Output power cords

IBM feature code

 

 

 

6635

7001

7002

2934

2933

2936

9880

9881

IBM part number

 

97P2653

97P2654

97P2663

97P2657

97P2658

53P4619

04N7027

97P3886

97P2659

97P2660

Input Voltage

Volts

208

-

-

-

-

-

-

-

 

 

Output voltage

Volts

208

-

-

-

-

-

-

-

 

 

Input/output frequency

Hz

50/60

-

-

-

-

-

-

-

 

 

Input voltage range

 

 

 

 

 

 

 

 

-

 

 

Minimum

Volts

177

-

-

-

-

-

-

-

 

 

Maximum

Volts

228

-

-

-

-

-

-

-

Quantity

 

Rectifier input

Amps

52

-

-

-

-

-

-

-

(2) 60 A,

 

Bypass input

 

 

 

 

 

 

 

 

 

3-phase,

 

Nominal amps

Amps

55.5

-

-

-

-

-

-

-

4-wire,

Quantity

AC output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IEC-309,

(3). See

Nominal

Amps

55.5

-

-

-

-

-

-

-

460R9W

FC 9881

10 minutes

Amps

69.4

-

-

-

-

-

-

-

with

description.

Battery

 

 

 

 

 

 

 

 

 

breakers

 

Nominal voltage

Volts

288

-

288

-

-

-

-

-

and

 

Max. charge

 

 

 

 

 

 

 

 

 

connec-

 

voltage @ 25°C

Volts

340

-

340

-

-

-

-

-

tors.

 

Charge current

Amps

7

-

-

-

-

-

-

-

 

 

Nominal discharge current

Amps

52

-

-

-

-

-

-

-

 

 

Total cell count

 

144

-

144

-

-

-

-

-

 

 

System efficiency

 

 

 

 

 

 

 

 

 

 

 

@100% load

%

92.4

-

-

-

-

-

-

-

 

 

@75% load

%

92.7

-

-

-

-

-

-

-

 

 

@50% load

%

92.9

-

-

-

-

-

-

-

 

 

Maximum heat dissipation

 

 

 

 

 

 

 

 

 

 

 

BTU/hr. (x1000)

 

3.9

-

-

-

-

-

-

-

 

 

kcal/hr.

 

990

-

-

-

-

-

-

-

 

 

Inverter efficiency

 

 

 

 

 

 

 

 

 

 

 

(full load)

%

94

-

-

-

-

-

-

-

 

 

Physical attributes (max.)

 

 

 

 

 

 

 

 

 

 

 

Width

in/cm

22/56

17/52

17/52

-

-

-

-

-

50 ft. (maximum cord)

Height

in/cm

45/114

45/114

45/114

-

-

-

-

-

 

 

Depth

in/cm

31/79

38/97

31/79

-

-

-

-

-

 

 

Weight installed

lb/kg

958/435

200/90

600/272

-

-

.5/.2

.5

.5/.2

20 lb. each connector

 

 

6 @

4 @

6 @

 

 

 

 

 

 

 

Point loading

lb/kg

160/73

50/230

145/100

N/A

N/A

N/A

N/A

N/A

-

-

Min/max qty per P93

 

-

1/1

0/2

0/4

0/4

0/2

0/2

0/2

1/1

0/6

Powerware

WORLDWIDE HEADQUARTERS

EUROPE/MIDDLE EAST/AFRICA

ASIA PACIFIC

LATIN AMERICA

8609 Six Forks Road

Denmark: 45.3677.7910

Australia/NZ: 612.9878.5000

Argentina: 5411.4343.6323

Raleigh, NC 27615 U.S.A.

Finland: 358.9.452.661

China: 86.21.6350.0606

Brazil: 55.11.3616.8500

Toll Free: 1.800.925.4426

France: 33.1.60.12.74.00

HK/Korea/Taiwan: 852.2745.6682

México: 5255.9171.7777

www.oem.powerware.com/ibm-ups

Germany: 49.7841.6660

India: 91.11.2649.9414 to 18

 

 

Italy: 39.02.66.04.05.40

Singapore/SEA: 65.6829.8888

 

CANADA

Norway: 47.23.03.65.50

 

 

Ontario: 416.798.0112

Sweden: 46.8.598.940.00

 

 

 

United Kingdom: 44.1753.608.700

 

 

Revised 01/04 Reprint 01/04