![Extended Battery Cabinets](/images/new-backgrounds/126451/1264519x1.webp)
Extended Battery Cabinets
Powerware offers a full line of battery cabinets for the Powerware P93.
ABattery cabinets may be
AIntegral configuration, which line up and match, is standard.1
A
ASlide trays and modular battery packaging makes periodic servicing easy.
ACabinets are UL 1778 listed.
AFlame retardant batteries meet UL 94V2 for computer room installations.
AWiring installation.2
A DC rated circuit breaker in each battery cabinet allows multiple battery strings to be serviced independently of each other, assuring back up power is always available to the UPS
Quick disconnects between battery tray assemblies reduce battery maintenance time.
Removable battery
1.Battery cabinets can be configured as line up and match or remotely located. Customer must provide wiring for remotely located cabinets. 2. If concurrent to P93 Field Installation, Powerware PN 103003671, IBM PN 97P3604.
Battery runtimes (in minutes)
|
|
|
|
| iSeries |
|
|
|
| pSeries |
|
| Storage | Cluster | |||
|
|
|
| 870 | 890 |
| 655 |
| 670 |
| 690 | 2105 | 1350 | 1600 |
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
| with |
|
|
|
|
|
|
| CEC + | CEC + | CEC + | 1 | 2 | 3 |
|
|
|
| expansion |
|
|
|
|
|
|
| I/O | I/O | I/O | node | nodes | nodes | up to | 8 way | 32 way | standard | enclosure |
|
|
|
| 10 kVA | 15 kVA | 20 kVA | 16 way | 16 way | 32 way | 1 I/O | 2 I/O | 3 I/O | 32 way | 1 I/O | 3 I/O |
|
| Contact | ||
| 7 kW | 10.5 kW | 14 kW | 6.8 kW | 4.9 kW | 8.3 kW | 3.2 kW | 6.4 kW | 9.6 kW | 6.5 kW | 3.2 kW | 10.5 kW | 6.4 kW | 13.8 kW | Powerware | ||
Internal battery | 45 | 26 | 17 | 48 | 79 | 31 | 110 | 50 | 27 | 49 | 110 | 26 | 50 | 17 |
|
|
|
(1) External |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
battery cabinet | 90 | 65 | 48 | 98 | 150 | 75 | 240 | 110 | 70 | 108 | 240 | 65 | 110 | 48 |
|
|
|
(2) External |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
battery cabinets | 155 | 90 | 75 | 166 | 240 | 130 | 400 | 180 | 96 | 172 | 400 | 90 | 180 | 75 |
|
|
|
Contact Powerware for runtime, application or configuration assistance.
Calculating runtime - a guide
Typical runtime is 15 minutes
Formula (runtime in minutes) = [business + (2 x system shutdown) + safety]
Business = _____
Shutdown ____ x 2 = _____
Safety = _____
Total = _____
| Powerware | IBM | IBM |
| Per P93 |
| Part Number | Feature Code | Part Number | Minimum | Maximum |
External Battery Cabinet | A13031 | 6635 | 97P2663 | 0 | 2 |
Additional options
AInput/output galvanic isolation
AVoltage matching transformers
ARemote status panel
ARemote EPO button