Important Safety Instructions

9

Electrical Recommendations: 120 V and 240 V Treadmills

Note: This is a recommendation only. NEC (National Electric Code) guidelines or local region electric codes must be followed.

You should have received a power cable that meets your local electrical code requirements along with the equipment. Precor treadmills must be connected to a 20 amp individual branch circuit that can be shared only with one PVS. If you need additional help with the power connections contact your Precor authorized dealer.

Important: An individual branch circuit provides a hot conductor and neutral conductor to a receptacle. The conductors must not be looped, "daisy-chained", or connected to any other conductors. The circuit must be grounded according to NEC guidelines or local region electric codes.

Figure 1: North American 120-volt, 20-amp power receptacle

Figure 2: North American 240-volt, 20-amp power receptacle

Page 11
Image 11
Precor P/N 300753-201 rev B manual Electrical Recommendations 120 V and 240 V Treadmills