Assembly - General

8)Slide the completed unit into its final location.

9)Place the Convection deck on the top of the firebox and fasten to the shroud top using the 2 screws provided (see Fig. 7).

Figure 7

10)Drop the catalytic thermometer in place on the top of the stove. The temperature probe inserts through the hole into the stove.

11)Connect the fan to a nearby AC plug outlet. NEVER run the AC fan cord under the fireplace insert.

INSTALLATION INTO FACTORY BUILT FIREPLACES

In addition to the general instructions presented throughout the manual you must take care to ensure the fol- lowing steps are correct when installing this insert into a factory built fireplace.

1)The factory built fireplace must be listed per UL 127 or ULC S620, and is installed and maintained to comply with all local building codes.

2)All clearances to combustibles must be maintained as shown on the label.

3)The installation must include a full-length liner, which is attached to the insert and to the chimney cap. For stoves installed in Canada, the factory built chimney must be lined from the outlet of the insert to the top of the chimney with a stainless steel liner that meets UL 1777 or ULC S635.

4)Means must be provided to prevent room air passage to the chimney cavity of the fireplace. This may be accomplished by sealing the damper area around the chimney liner, or sealing the fireplace front.

5)The airflow within and around the fireplace shall not be altered by the installation of the insert

(i.e.: no louvers or cooling air outlet ports are blocked).

6)No alterations of the factory built fireplaces are allowed except as follows:

a)External trim which do not affect the operation of the fireplace may be removed providing they can be stored on or within the fireplace for reassembly if the insert is removed.

b)The chimney damper may be removed to install the chimney liner.

7)Circulating air chambers in a steel fireplace liner or metal heat circulator shall not be blocked.

8)Means must be provided for removal of the insert to clean the chimney flue.

9)If the insert protrudes from the front of the fireplace a supporting means must be installed and all clear- ance requirements met.

10)A permanent metal warning label must be attached to the back of the fireplace stating that the fireplace must be restored to the original condition for safe use without the insert.

PI-1010A

Page 20

DATE PRINTED: 2/8/05

Revision Date: 02/01/05

Page 20
Image 20
Princess PI 1010A manual Installation Into Factory Built Fireplaces