OPERATING YOUR HEATER

OPERATING YOUR HEATER

THERMOSTAT MODELS

 

 

 

 

 

nLIGHTINGn

 

 

 

 

 

a qualified service person or gas

 

 

 

 

INSTRUCTIONS

 

 

 

 

 

supplier

for

repairs.

 

 

 

nFOR YOUR SAFETYn

1.

STOP!

 

Read

 

the

safety

 

Note: If pilot goes out, repeat

 

 

 

 

steps 3

through 7. This

heater

 

READ BEFORE LIGHTING

2.

information on the side of heater.

 

has

a

safety

interlock system.

 

 

 

 

 

 

 

 

 

 

 

 

 

Make

sure

equipment

shutoff

 

Wait one(1)minute before lighting

 

WARNING:

If

you

do

not

 

valve

is fully

open.

 

 

 

 

 

 

 

3.

 

 

 

 

 

 

pilot

again.

 

 

 

 

 

follow these instructions exactly, a

Turn

control

knob clockwise

 

 

8.

Turn control knob counterclock-

fire

or

explosion

may

 

result

 

to the

OFF

position.

 

 

 

 

 

 

 

 

 

 

 

wise

 

to desired heating level.

causing property damage,personal

4.

Wait

 

five(5)

minutes to

clear

 

 

 

 

The main burner should light.

injury or

loss

of

life.

 

 

 

 

 

 

out any gas. Then smell for gas,

 

 

 

 

 

 

 

 

Set control knob to any heat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

including

near the floor. If you

 

A. When lighting the pilot, follow these

 

 

level between HI and LO.(see

 

smell gas, STOP! Follow “B” in the

 

 

 

Figure 20)

 

 

 

 

 

instructions exactly.

 

 

 

 

 

 

 

 

safety information on the side

 

of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION: Do not try to ad-

B.

BEFORE

LIGHTING

smell all

 

heater.

If

 

you

don’t

smell

 

 

around the

appliance area

for

gas.

 

gas, go to the next

step.

 

 

 

just heating levels by using

the

 

 

 

 

equipment shutoff valve.

 

 

Be

sure

to

smell

next

 

to

the

floor

5.

Turn

control

knob counterclock-

 

 

 

 

 

 

 

 

 

 

 

 

 

because

some gas

is

heavier

than

 

wise

 

 

to the PILOT position.

 

 

 

 

 

 

 

 

 

 

 

Press in

 

control

knob

for

 

 

 

 

 

 

 

 

 

 

air

and will settle on

the

floor.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

five(5) seconds. (see Figure 20).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHAT TO DO IF YOU SMELL GAS

 

Note: You

 

may

be

running

 

 

 

 

 

 

 

 

 

 

 

this heater for the first time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Do

not

try

to

light

any

 

after hooking

up to

gas supply.

 

 

 

 

 

 

 

 

 

 

 

If

so,

the control

knob

may

 

 

 

 

 

 

 

 

 

 

 

appliance.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

need

 

to

be

pressed in for

30

Figure 20 - Control Knob in The

Do

not

touch

any

 

electric

 

 

 

 

seconds. This will allow air to

OFF Position

 

 

 

 

 

 

switch,

do

not

use any

phone

 

bleed from the gas system.

 

 

 

 

 

 

 

 

 

 

 

 

 

in your building.

 

 

 

 

 

 

If control knob does

not pop

 

 

 

 

 

 

 

 

 

 

Immediately

call

 

your

gas

 

up when released, contact a

 

 

 

 

 

 

 

 

 

 

 

supplier

from

a

 

neighbor’s

 

qualified

service

person

 

or

 

 

 

 

 

 

 

 

 

 

 

phone. Follow the gas

 

gas

supplier

for

repairs.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6.

With

 

control

knob pressed

 

in,

 

 

 

 

 

 

 

 

 

 

 

supplier’s

instructions.

 

 

 

push

down

and

release ignitor

 

 

 

 

 

 

 

 

 

 

If

you

cannot

reach

your gas

 

 

 

 

 

 

 

 

 

 

 

 

button. This

will

light pilot. The

 

 

 

 

 

 

 

 

 

 

 

supplier,

call

 

the

 

fire

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

pilot

is attached

to

the

front

 

of

 

 

 

 

 

 

 

 

 

 

 

department.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

burner. If

needed, keep pressing

 

 

 

 

 

 

 

 

 

 

C.

Use

only

your

hand to

push in

 

Figure 21 - Pilot

 

 

 

 

 

ignitor button until pilot lights.

 

 

 

 

or turn the gas control knob.

Note: If

pilot does not stay

lit, refer

 

 

nTO TURN OFFn

 

 

Never use tools. If the knob will

to Troubleshooting, pages 14 through

 

 

 

 

not push in or turn by hand, don’t

16. Also contact a qualified service

 

GAS TO APPLIANCE

 

try

to

repair

it , call

 

a

qualified

person

or

gas

supplier

for

repairs.

Shutting

Off Heater

 

 

service technician or gas supplier.

Until repairs are made, light pilot with

1.

Turn

control

knob clockwise

Force

or

attempted

 

repair

may

match.To light pilot with match, see

2.

to the OFF position.

to the

result

in

a

fire

or

explosion.

 

 

Manual Lighting Procedure.

 

 

 

 

Turn

off

all

electric power

 

 

7.

Keep

control

knob

pressed

 

appliance

if

 

service

is

to

D.

Do

not use

this

 

appliance if

 

 

 

 

be performed.

 

 

 

 

any part

has

been under

water.

 

in

for

30 seconds after lighting

 

 

 

 

 

 

pilot. After 30 seconds,

release

Shutting

Off Burner Only (pilot

Immediately call a

qualified

service

 

 

control

knob.

 

 

 

 

 

 

 

 

stays lit )

 

 

 

 

 

 

technic ian

to

 

inspect

the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If

control knob does not pop

Turn control knob clockwise

 

to

appliance and to replace any part of

 

up

when

released, contact

the PILOT position.

 

 

 

 

the control system and any gas

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

control which has been

under

water.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 22 - Burner Patterns

12