LIGHTING INSTRUCTIONS

WARNING:FOR YOUR SAFETY READ BEFOR LIGHTING

1.STOP! Read the safety information above.

2.Make sure manual shutoff valve is fully open.

3.Press in and turn control knob clockwise 90 degree to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas around log set and near floor. If you smell gas, STOP! Follow the safety information above. If you don’t smell gas, go on to the next step.

5.Turn control knob counterclockwise 90 degree to the PILOT position and press in. Keep con- trol knob pressed in for five(5) seconds.

Note: You may be running this log set for first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system.

6.With control knob pressed in, push down and re- lease ignitor button. This will light the pilot. The pi- lot is attached to the side of the front burner. If needed, keep pressing ignitor button until pilot lights.

NOTE: If pilot does not stay lit, contact a qualified service person or PRO-COM’s 800# on the back of this manual. Until repairs are made, light pilot with the piezo.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Note: If pilot goes out, repeat steps 3 through 7.

If control knob does not pop up when released, con- tact a qualified service person or PRO-COM’s 800# on the back of this manual.

8.Turn control knob counterclockwise 90 degree to the ON position. Burner should light. If burner does not light, call a qualified service person or PRO-COM’s 800# on the back of this manual.

WARNING: If you do not follow these in- structions exactly, a fire or explosion may result causing property damage, personal in- jury or loss of life.

TO TURN OFF GAS TO APPLIANCE Shutting Off Appliance

1. Turn control knob clockwise

90 degrees to

the PILOT position.

2.Press in and turn control knob clockwise 90 degrees to OFF position.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise 90 degrees to the PILOT position.

Fig12 The operationg board

MAINTENANCE AND STORAGE

1.Storage of an appliance indoors is permissible only if the gas supply system is disconnected and removed from the appliance. .

2.Have the heater inspected by qualified service man before each use or at least annually.

3.Check the POL fitting for any damage before each use and replace if any damage is found.

4.Spiders and insects can nest and live in outdoor appliances, especially in the burners and orifices. This will interrupt the normal flow of LP gas to the heater and can be a very dangerous situation. Inspect for insect infiltration of burner/orifice when one of the following occurs:

A.The smell of gas along with predominating yel- low tipping of the burner flames.

B.Heater can not reach desired temperature.

C.Uneven burner flow.

D.Burner makes popping noises during normal use or shutdown.

5. Adopt rainproof cover (provided with the heater)

8to avoid rust of heater when not in use.