M4 FEATURES
M4 Multi-Zone Audio Amplifier/Controller
The M4 is a
Communication port.
EXPANSION PORTS
RJ45 jacks provide for connection of specialized RS485 controlled products and for looping to
PHONE PAGE IN Jack | DOORBELL/STATUS IN 1 & 2 Jacks | CONTROL PORT & FIRMWARE UPGRADE Switch |
This jack provides input porting for audio feeds from | These 3.5mm mini phone trigger inputs work in | 3.5mm |
door mikes or other forms of phone or doorbell | conjunction with the PHONE PAGE IN jack. When | programming is accomplished via this port using Proficient Editor in conjunction |
paging. The jack is programmable by Proficient | triggered, the phone inputs can be turned on as | with the mating Transfer Cable. It also accommodates factory firmware updates |
Editor, to turn on as events, when triggered by the | programmed by Proficient Editor. If audio paging is | in conjunction with the FIRMWARE UPGRADE OFF/ON Switch. Be sure to leave |
DOORBELL/STATUS IN Jack. | not required, these 1 & 2 jacks may also be pogrammed | this switch in the OFF position at all times, except, as instructed within Proficient |
| as STATUS inputs for power management of source or | Editor, when you are doing a firmware update. Such updates ensure that you can |
| zone components. They accept input levels of 3V to 30V | always have the latest functionality improvements in the field. Another function of |
| AC or DC for the trigger ON condition. The voltage level | this port is that you can control installed system components with |
| must drop below 1V AC or DC for the OFF condition. | data via touch panels or computers using RS232 protocol. |
Figure 2 |
|
|
M4 Rear Panel Features |
|
|
|
| EXPANSION PORTS |
|
| RS232 |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| FIRMWARE | COMMON |
| COMMON |
| |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| 1 |
| 2 | UPGRADE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| LO | HI |
| M4 | ||
|
|
|
|
|
|
|
|
|
|
| CONTROL |
|
| |||
CONTACT CLOSURE |
|
|
|
|
|
|
| PHONE (PAGE IN) | DOORBELL / STATUS IN | OFF ON | IR OUT | STATUS OUT: 0 to +12V | ||||
|
|
|
|
| DATA I/O |
| PORT | |||||||||
| SOURCE 1 |
|
|
| SOURCE 2 |
| ||||||||||
OUT |
| OUT |
| OUT | SOURCE 3 | OUT | SOURCE 4 | OUT | SOURCE 5 | OUT | SOURCE 6 | Riverside, CA. USA | ||||
|
|
|
|
|
|
|
|
| Made in Taiwan |
COMMON IR OUTPUT & HI/LO Switch
3.5mm mini phone jack provides a common IR output derived from all of the zone IR inputs and from keypad initiated IR commands derived from the internal IR library. High or low IR power output is set by means of the HI/LO switch. Set it to the LO setting when driving standard low power emitters (i.e, Proficient IR single flasher). Set it to the HI position when driving a high power emitter (i.e, a blaster) for teaching IR commands into learning remotes. Caution: The HI position will damage or destroy low power emitters!
COMMON STATUS OUT Port
This 3.5mm mini phone jack will go high (+12V DC) when any zone is turned ON and will go LOW (under 1V DC) when the last zone is turned OFF. The max. output of this jack is 100 mA at 9.5V DC.
IR OUT Jacks
These 3.5mm mini phone jacks, one for each source, provide dedicated IR output to specific source components. When a source is selected on a keypad, IR function commands are
additional M4 controllers for zone expansion capability.
CONTACT CLOSURE
Provides a single pole dry relay contact to activate any device that can be controlled or triggered by a switch closure. The closure can be programmed within Proficient Editor to be activated by keypad presses,
IR |
|
|
|
|
|
|
|
|
|
| INPUTS | IR |
|
|
|
|
|
|
|
|
|
| INPUTS | IR |
|
|
|
|
|
|
|
|
|
| INPUTS | ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||||
|
|
| L |
|
| R |
|
|
| L |
|
| R |
|
|
| L |
|
| R | |||||||||||||||||||||||||||
LOOP |
|
|
|
|
|
|
|
|
|
| LOOP | LOOP |
|
|
|
|
|
|
|
|
|
| LOOP | LOOP |
|
|
|
|
|
|
|
|
|
| LOOP | ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||
L |
|
|
|
| R |
|
| L |
|
|
|
| R |
|
| L |
|
|
|
| R |
| |||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| VC |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| VC |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| VC |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| NVC |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| NVC |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| NVC |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
| IR OUT |
|
|
|
|
|
|
|
|
|
|
|
| IR OUT |
|
|
|
|
|
|
|
|
|
|
|
| IR OUT | |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| KEYPAD |
|
|
| ZONE 1 |
|
|
|
|
|
| KEYPAD |
|
|
| ZONE 2 |
|
|
|
|
|
| KEYPAD |
|
|
| ZONE 3 | |||||||||||||||
|
|
|
|
|
| SPKRS |
|
|
|
|
|
|
|
|
|
| SPKRS |
|
|
|
|
|
|
|
|
|
| SPKRS |
|
|
|
| |||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
IR |
|
| INPUTS | IR |
|
| INPUTS | IR |
|
| INPUTS |
|
|
|
|
|
| ||||||
L |
| R | L |
| R | L |
| R | |||
LOOP |
|
| LOOP | LOOP |
|
| LOOP | LOOP |
|
| LOOP |
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
LR
VC
NVC
IR OUT | 120V 60Hz 1.8A ~ |
| FUSE: T5AL 250V |
KEYPAD
ZONE 4
SPKRS
routed directly to that source. This prevents
IR LOOP Jacks
These six 3.5mm mini phone jacks, one for each source, are provided exclusively for zone expansion capability when using two or more M4 controllers. They permit the source IR signals from the added zones to be carried to the source component emitters.
L & R Audio IN & LOOP Jacks
These RCA jacks – four for each source – provide audio signal inputs and buffered loop outputs, for each
Command Library IR, or within macros for Momentary, Toggle and Open/ Close Paired operations.
+ L – – R + | + L – – R + | + L – – R + | + L – – R + |
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
source. The buffered outputs can be used to drive local components or loop the signals to the additional zone inputs of other M4 controllers when using them for source expansion.
L & R PRE-OUT Jacks
These RCA jacks provide line level audio outputs for driving external power amplifiers for additional rooms within zones, where needed.
2
Keypad Zone Inputs |
| L & R SPEAKERS Terminals | IR OUT |
These RJ45 terminals allow for easy |
| These | This 3.5mm mini jack, one for each zone, provides dedicated Zone IR |
connection of the |
| terminals accept wire sizes from 14 to | output initiated from the respective zone inputs. They may control |
from keypads in the various rooms. |
| 28 AWG. They allow quick connection of | specific zone components when you want to prevent the control of it |
Normally this is accomplished using |
| the internal amplifiers to stereo pairs of | from the other zones. |
CAT5 cable with |
| speakers in the various zone rooms. |
|
up to 1000'. | 3 |
| 4 |
VC-NVC Switch
The audio output from the
IEC Type AC
Mains receptacle and fuse mates with included AC power cord. Also houses the rear panel replaceable AC mains fuse (T5AL 250V for 120V, and T2.5AL 250V for 230V/240V)
5