ProForm PFSB43140 user manual Draining the Pumps, Replacing the LED Light, Winter USE and Care

Models: PFSB43140

1 24
Download 24 pages 7.96 Kb
Page 19
Image 19

DRAINING THE PUMPS

After the hydrotherapy spa is drained, the jet pumps should also be drained if the spa will be stored for more than thirty days or if it may be exposed to freez- ing temperatures.

REPLACING THE LED LIGHT

Remove the access panels (see ATTACHING AND REMOVING THE ACCESS PANELS on page 18). Make sure the spa power is turned off. Next, locate the light housing. Turn the light housing counterclockwise and remove it from the spa shell.

Shut off the power to

 

the spa, at the circuit

 

breaker or GFCI. To

 

drain the jet pumps,

 

remove the access pan-

 

els from the spa (see

 

ATTACHING AND

Collar

REMOVING THE

ACCESS PANELS on

 

page 18). Locate the jet

 

pumps inside the spa.

 

Loosen the indicated

 

Light Housing

LED

Light

Light

Housing

collar on each of the pumps.

WINTER USE AND CARE

The hydrotherapy spa is designed for year-round use. If you decide to store the spa for the winter, store it in a warm, dry location. Follow the steps below to winter- ize the spa.

1.Make sure the power to the spa is turned off.

2.Drain the spa (see DRAINING THE HYDROTHER- APY SPA on page 18).

3.Remove all remaining water from the spa shell. Dry the spa shell with towels.

4.Set the air controls to the lowest setting. Use a wet/dry vacuum to pull any remaining water from the system. To do this, place the vacuum nozzle over each jet, starting with the highest jet and fin- ishing with the lowest jet.

5.Set the air controls to the highest setting and repeat step 3.

6.Drain the pumps (see DRAINING THE PUMPS on this page). Once the water is drained from the pumps, place the vacuum nozzle over the drainage hole in the pumps and vacuum any additional water from the pumps. Note: For additional pro- tection, remove the pumps/motors from the spa and store them in a climate-controlled room.

7.Clean the spa shell (see page 16).

8.Clean the filter (see page 16).

9.Shut the power off at the breaker. Label the breaker in such a way that the breaker will not

be turned on accidentally.

10. Reattach the access panels and the spa cover.

To replace the LED light, pull the old LED light out of the housing and insert a new LED light. Reattach the light housing to the spa shell. Reattach the access panels to the spa.

19

Page 19
Image 19
ProForm PFSB43140 user manual Draining the Pumps, Replacing the LED Light, Winter USE and Care, Be turned on accidentally