F. ADJUSTMENT PROCEDURE

 

ITEM

Test Meter

 

Adjusting

 

 

Test Point

Operation

Program Menu.

Pattern

 

 

Value

 

 

 

 

 

 

 

 

 

 

 

B+

Digital Voltmeter

1. Make the adjustment to the value shown at right

15.5V

A

Adjust

D510 Negative

by turning the VR501 on the main PCB.

±0.2V

 

Crosshatch Pattern

 

 

 

 

 

(31.5KHz,640x480)

 

 

 

 

 

 

 

 

 

High Voltage

Digital Voltmeter

1. Turn the power switch of the monitor OFF.

26.0KV

 

Adjust

High Voltage

2. Connect high voltage probe to Anode Cap and

(17”,19”)

B

 

Probe

GND.

25.0KV

 

Anode Cap-GND

3. Turn the power switch of the monitor ON.

±

0.1KV

 

 

 

 

 

 

 

Crosshatch Pattern

(15 minutes)

(15”)

 

 

4. Make the adjustment to the value shown at right

 

 

 

 

(31.5KHz,640x480)

 

 

 

 

 

by turning the VR601 on the main PCB.

 

 

 

 

 

 

 

 

Preset

Crosshatch

1. Turn the power switch of the monitor OFF.

Contrast :

 

Adjust

(31.5KHz,640x480)

2. Hold encorder key,then turn the power switch of

 

MAX.

 

 

 

the monitor ON.(one key type)

Brightness

 

 

 

Hold MENU key,then turn the power switch of

 

MAX.

 

 

 

the monitor ON.(four key type)

H-Size :

 

 

 

3. Turn encorder/MENU key,make sure into preset

260mm(15”)

 

 

 

picture,if not ,please return 1-2.

310mm(17”)

 

 

 

4. Please following the procedure of selection and

360mm(19”)

 

 

 

adjusting an item using the OSD system as below

V-Size :

 

 

 

steps for main function adjusent.

190mm(15”)

 

 

 

One key model :

230mm(17”)

 

 

 

Step 1 : Press and relese the OSD control knob to

270mm(19”)

 

 

 

activate the OSD menu.

H-Posi. :

C

 

 

Step 2 : Turn the knob to highlight the desired option

Center

 

 

of OSD icon.

V-Posi :

 

 

 

Step 3 : Press and release the knob again to access

Center

 

 

 

the option. The color of the inner area of the

 

 

 

 

 

OSD will changed from blue to green.

 

 

 

 

 

Step 4 : To make your adjustment,turn the knob

 

 

 

 

 

clockwise to increase or countclockwise

 

 

 

 

 

to decrease the setting.

 

 

 

 

 

Step 5 : Press and release the knob again to store

 

 

 

 

 

the change.the color of the inner area will

 

 

 

 

 

go back to blue.You can select EXIT icon

 

 

 

 

 

and press the knob the exit the OSD menu.

 

 

 

 

 

 

 

 

11