ITEM
Program Menu.
﹟Test Meter ﹡Test Point ﹫Pattern
Operation
Adjusting
Value
Dynamic | ﹟Oscilloscope | 1. Set the contrast to MAX.,and adjustment | VF : | |
Focus | ﹡FBT Pin14 |
| Brightness to the raster just appear. | 140(17”) |
H Adjust | ﹫Full White | 2. | Make the adjustment to the value shown at right | 150(19”) |
| (31.5KHz,640x480) | 3. | by adjust the VF on the OSD menu. | |
| Make the check to the value shown at right by | HF : | ||
|
|
| adjust the HF on the OSD menu. | 430(17”) |
|
|
|
| 450(19”) |
|
|
|
|
Purity | ﹫Magenta color | 1. Adjust the purity magnet is in magneta color. | |
Adjust | (31.5KHz,640x480) | 2. Turning two overlapping pawels in opposite | |
I |
| 3. | directions. |
|
| Move them until they are at the same angle, | |
|
|
| 9 o’clock and 3 o’clock respectively. |
|
|
| |
Static | ﹫Magenta color | 1. Open the two pawels of the 4 pole magnets to | |
Convergence | (31.5KHz,640x480) |
| allow the red and blue vertical lines to unite. |
Adjust |
| 2. Open and rotate the two pawels at a contrast | |
|
|
| angle so that the red and blue horizontal lines |
|
| 3. | can unite. |
|
| If the vertical lines deviates,open the two powals | |
J |
|
| at the deviation position and make a monitor |
| 4. | adjustment by changing its angle. | |
|
| Display white crosshatch pattern. | |
|
| 5. | Make the red and blue vertical lines at the |
|
|
| center unite with the green by opening the two |
|
| 6. | 6 pole pawels. |
|
| Rotate the two pawels at contrast angle so that | |
|
|
| the red and blue horizontal lines can unite with |
|
| 7. | the green. |
|
| If the vertical lines deviate,change the angle of | |
|
|
| Pawels from the deviation position. |