PYLE Audio PZR10XA, AZR6XA, PZR50XA, PZR30XA owner manual Installation Guidelines

Models: PZR10XA PZR50XA PZR30XA AZR6XA

1 4
Download 4 pages 17.14 Kb
Page 3
Image 3

INSTALLATION GUIDELINES

Connecting the GND (GROUND) screw terminal Connecting a mixer or preamplifier may cause excessive noise or hum in the amplifier output. To prevent this, connect one end of a low-capacitance shield wire to the amplifier's ground screw (on the rear panel). Then connect the other end of this wire to the ground terminal on the mixer or preamplifier enclosure.

 

 

 

 

PREAMP OR MIXER

 

OUTPUTS

 

CAUTION:

 

CH-2

CH-1

 

CAUTION:

 

 

 

 

CAUTION:

 

~ AC 120V 60H

BRIDGE

 

INPUTS

CAUTION

 

CH-2

CH-1

GND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GROUND

 

 

 

 

 

 

 

 

 

 

 

 

 

LOW CAPACITANCE SHIELDED WIRE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SCREW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PREAMP OR MIXER

LOW CAPACITANCE SHIELD WIRE

GROUND SCREW

Input connections

These amplifiers accept a board range of input sources, including Compact Disc (CD,DVD) players; Cassette, Reel- to-Reel or other tape players; Radio Tuners; Equalizers; Signal Processors.

Connecting a CD, DVD, tape player or tuner

In a normal installation, one would use the RCA JACKS for connecting a CD player, DVD player,tape player or tuner.

 

OUTPUTS

BALANCED)

INPUTS

 

 

 

HOT(+) COLD(-

GND(+)

 

CAUTION: DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE.

CH-2

CH-1

 

FOR CONTINUED PROTECTION AGAINST RISK OF FIRE

 

 

 

 

 

CAUTION: REPLACE ONLY WITH SAME TYPE FUSE.

 

 

2

1

 

CAUTION: PLUG WITH AN EXTENSION CORD RECEPTACLE

 

 

 

 

 

TO PREVENT ELECTRIC SHOCK DO NOT USE THIS (POLARIZED)

 

 

3

 

 

OR OTHER OUTLET UNLESS THE BLADES CAN BE FULLY

 

 

 

 

 

INSERTED TO PREVENT BLADE EXPOSURE

~ AC 120V 60HZ

BRIDGE

 

 

 

INPUTS

CAUTION

 

CH-2

CH-1

 

 

 

ELECTRIC SHOCK

 

 

 

RISK OFDO NOT OPEN

GND

 

 

 

 

CH-2

CH-1

MONO

GROUND LIFT

 

 

 

 

 

STEREO BRIDGE

GROUND LIFT

EQ OR MIXER

use XLR/6.35 mm combo jacks

use RCA jacks

CD PLAYER, DVD , TAPE PLAYER OR TUNER

use RCA jacks

CD PLAYER, TAPE PLAYER OR TUNER

Connecting an equalizer or external signal processor

Connect the processor's OUT to the amplifier's IN connector.

 

OUTPUTS

BALANCED)

INPUTS

 

 

 

HOT(+) COLD(-

GND(+)

 

CAUTION: DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE.

CH-2

CH-1

 

FOR CONTINUED PROTECTION AGAINST RISK OF FIRE

 

 

 

 

 

CAUTION: REPLACE ONLY WITH SAME TYPE FUSE.

 

 

2

1

 

CAUTION: PLUG WITH AN EXTENSION CORD RECEPTACLE

 

 

 

 

 

TO PREVENT ELECTRIC SHOCK DO NOT USE THIS (POLARIZED)

 

 

3

 

 

OR OTHER OUTLET UNLESS THE BLADES CAN BE FULLY

 

 

 

 

 

INSERTED TO PREVENT BLADE EXPOSURE

~ AC 120V 60HZ

BRIDGE

 

 

 

INPUTS

CAUTION

 

CH-2

CH-1

 

 

 

ELECTRIC SHOCK

 

 

 

RISK OFDO NOT OPEN

GND

 

 

 

 

CH-2

CH-1

MONO

GROUND LIFT

 

 

 

 

 

STEREO BRIDGE

GROUND LIFT

EQ OR MIXER

EQ OR MIXER

EQ OR MIXER

use XLR/6.35mm combo jacks

Stereo or Mono Inputs

Your Pyle Pro amplifier can be operated in Stereo, Mono or Bridged mode, depending on the input source. If the input signal is mono, slide the Stereo/Mono/Bridged selector switch to MONO and the signal will be routed through both channels. If you wish to run the amplifier in bridged output mode, slide the switch to Bridged.

Speaker connections

You can connect 4 Ohm, 8 Ohm or 16 Ohm speakers to Channel 1 and/or Channel 2 of the amplifier. If you connect two pairs of speakers, be sure to follow these guidelines:

Speakers which are connected to the same channel are part of a pair, and must be of the same impedance.

Speakers connected to different channels are NOT part of a pair, and can be of different impedances.

1.Prepare the speaker wire by removing about 1 inch of insulation from the end of the speaker wire you intend to connect to the amplifier. Then twist the exposed wire to secure all the wire strands.

NOTE: Use 16-gauge speaker wire for lengths up to25 feet; 14-gauge wire for lengths over 25 feet. It is recommended that you use the shortest length of wire possible.

2.Connect the speaker wires to the speaker's positive and negative terminals.

NOTE: Most speaker terminals are either color-coded or have a mark that indicates the terminal's polarity. Usually positive terminals are red or have a plus symbol (+), and negative terminals are black or have a minus symbol (-).

3.Connect the speaker wires to the amplifier's left and right speaker terminals according to the terminal color

polarity.

STEREO OPERATION

SWITCH IN “STEREO” POSITION

CH 2

 

 

 

CH 1

 

 

 

OUTPUTS

BALANCED)

INPUTS

CAUTION: DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE.

 

HOT(+) COLD(-

GND(+)

 

CH-2

CH-1

 

FOR CONTINUED PROTECTION AGAINST RISK OF FIRE

 

 

 

 

 

CAUTION: REPLACE ONLY WITH SAME TYPE FUSE.

 

 

2

1

 

CAUTION: PLUG WITH AN EXTENSION CORD RECEPTACLE

 

 

 

 

 

TO PREVENT ELECTRIC SHOCK DO NOT USE THIS (POLARIZED)

 

 

3

 

 

OR OTHER OUTLET UNLESS THE BLADES CAN BE FULLY

 

 

 

 

 

INSERTED TO PREVENT BLADE EXPOSURE

~ AC 120V 60HZ

BRIDGE

 

 

INPUTS

CAUTION

 

CH-2

CH-1

 

 

 

ELECTRIC SHOCK

 

 

 

RISK OFDO NOT OPEN

GND

 

 

 

 

CH-2

CH-1

MONO

GROUND LIFT

 

 

 

 

 

STEREO BRIDGE

GROUND LIFT

STEREO SIGNAL SOURCE

CAUTION! Do not use balanced and unbalanced inputs simultaneously!!

CH 2

CH 1

STEREO SIGNAL SOURCE

CAUTION! Do not use balanced and unbalanced inputs simultaneously!!

MONO OPERATION

SWITCH IN “MONO” POSITION

CH 2

 

 

 

CH 1

 

 

OUTPUTS

BALANCED)

INPUTS

CAUTION: DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE.

HOT(+) COLD(-

GND(+)

 

CH-2

CH-1

 

FOR CONTINUED PROTECTION AGAINST RISK OF FIRE

 

 

 

 

 

CAUTION: REPLACE ONLY WITH SAME TYPE FUSE.

 

 

2

1

 

CAUTION: PLUG WITH AN EXTENSION CORD RECEPTACLE

 

 

 

 

 

TO PREVENT ELECTRIC SHOCK DO NOT USE THIS (POLARIZED)

 

 

3

 

 

OR OTHER OUTLET UNLESS THE BLADES CAN BE FULLY

 

 

 

 

 

INSERTED TO PREVENT BLADE EXPOSURE

~ AC 120V 60HZ

BRIDGE

 

 

INPUTS

CAUTION

 

CH-2

CH-1

 

 

 

ELECTRIC SHOCK

 

 

 

RISK OFDO NOT OPEN

GND

 

 

 

 

CH-2

CH-1

MONO

GROUND LIFT

 

 

 

 

 

STEREO BRIDGE

GROUND

LIFT

 

 

 

 

 

 

MONO SIGNAL SOURCE

 

 

 

 

 

 

USE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHANNEL 1

 

 

 

 

 

 

 

INPUT ONLY

CAUTION! Do not use balanced and unbalanced inputs simultaneously!!

CH 2

CH 1

MONO SIGNAL SOURCE

 

 

USE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHANNEL 1

 

 

 

 

 

 

 

 

 

 

 

 

INPUT ONLY

CAUTION! Do not use balanced and unbalanced inputs simultaneously!!

Bridged Mode Operation

This amplifier can operate in a mono bridged output mode, if your speakers can handle the following power output levels:

As shown in the diagram below, connect the speaker's positive

(+)to the amplifier's red speakers left (1/2) terminals and negative (-) to red speakers right (1/2) terminals.

The speaker right (+) on the amplifier is used as a negative (-) terminal for a bridged connection.

NOTE: The extra amplifier output of 6.35mm phone jacks can not be used for the bridged connection. It can only be used in normal (non-bridged) operation as a stereo speaker output.

MONO BRIDGED OPERATION

SWITCH IN “BRIDGED” POSITION

DO NOT USE

BLACK TERMINALS

OUTPUTS

BALANCED)

INPUTS

 

 

HOT(+) COLD(-

GND(+)

 

CAUTION: DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE.

CH-2

CH-1

 

FOR CONTINUED PROTECTION AGAINST RISK OF FIRE

 

 

 

 

 

CAUTION: REPLACE ONLY WITH SAME TYPE FUSE.

 

 

2

1

 

CAUTION: PLUG WITH AN EXTENSION CORD RECEPTACLE

 

 

 

 

 

TO PREVENT ELECTRIC SHOCK DO NOT USE THIS (POLARIZED)

 

 

3

 

 

OR OTHER OUTLET UNLESS THE BLADES CAN BE FULLY

 

 

 

 

 

INSERTED TO PREVENT BLADE EXPOSURE

 

BRIDGE

 

 

 

INPUTS

CAUTION

~ AC 120V 60HZ

 

CH-2

CH-1

 

 

 

ELECTRIC SHOCK

 

 

 

RISK OFDO NOT OPEN

GND

 

 

 

 

CH-2

CH-1

MONO

GROUND LIFT

 

 

 

 

 

STEREO BRIDGE

GROUND

LIFT

 

 

 

 

 

 

MONO SIGNAL SOURCE

 

 

USE

 

 

 

 

CHANNEL 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT ONLY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DO NOT USE

BLACK TERMINALS

MONO SIGNAL SOURCE

 

 

USE

 

 

 

 

 

 

 

 

 

CHANNEL 1

 

 

 

 

 

 

 

 

 

 

 

 

INPUT ONLY

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION! Do not use balanced and unbalanced inputs simultaneously!!

2 – PYLE PRO PZR6XA/10XA/30XA/50XA Amplifier Owner’s Manual

 

PYLE PRO PZR6XA/10XA/30XA/50XA Amplifier Owner’s Manual – 3

 

 

 

 

Page 3
Image 3
PYLE Audio PZR10XA, AZR6XA, PZR50XA, PZR30XA owner manual Installation Guidelines