BACK PANEL FEATURES

BACK PANEL FEATURES

(7) IEC MAINS CONNECTOR

This is a standard IEC power connector. An AC mains cord having the appropriate AC plug and ratings for the intended operating voltage is included in the carton.

U.S. DOMESTIC AC MAINS CORD

The mains cord supplied with the unit is a heavy-duty, 3-conductor type with a conventional 120 VAC plug with ground pin. It should be connected to an independent circuit capable of continuously supporting at least 15 amps. This is particularly critical for sustained high-power applications. If the outlet used does not have a ground pin, a suitable grounding adapter should be used and the third wire grounded properly.

Never break off the ground pin on any equipment. It is provided for your safety.

The use of extension cords should be avoided but, if necessary, always use a 3-wire type with at least a #14 AWG wire size. The use of lighter wire will severely limit the power capability of this amplifiers. Always use a qualified electrician to install any new electrical equipment. To prevent the risk of shock or fire hazard, always be sure that the amplifier and all associated equipment is properly grounded.

NOTE: FOR UK ONLY.

If the colors of the wires in the mains lead of this unit do not correspond with the colored markings identifying the terminals in your plug, proceed as follows (1) The wire that is colored green and yellow must be connected to the terminal that is marked by the letter E, the earth symbol, colored green, or colored green and yellow. (2) The wire that is colored blue must be connected to the terminal that is marked with the letter N or the color black. (3) The wire that is colored brown must be connected to the terminal that is marked with the little L or the color red.

(8) BINDING POST OUTPUTS

Shockproof binding post speaker outputs are provided on the amplifier. For each channel, the outputs are in parallel and the speaker connection cables can be terminated with banana plugs or stripped wires for use in the binding post terminals, or can be connected using the Speakon outputs (9). For sustained high-power applications, either outputs can be used, however, exercise care to assure the correct speaker phasing. The red binding posts are the signal outputs from each channel, and the black binding posts are chassis ground. The red binding post should be connected to the positive inputs of the associated loudspeakers. For BRIDGE mode operation, only the red binding posts are used and the associated loudspeaker load is connected between the two red posts.

WARNING: Regardless of what connections are used, the minimum parallel speaker load should always be limited to 2 ohms per channel or 4 ohms BRIDGE mode for any applications. Operation at loads of 4 ohms per channel, or 8 ohms BRIDGE mode, is more desirable for sustained operation applications because the amplifier will run much cooler at this loading. Operation above 4 ohms per channel and even open-circuit conditions can always be considered safe, but sustained operation at loads below 2 ohms could result in temporary amplifier shut down due to the thermal limit circuitry.

Page 6
Image 6
PYLE Audio PTA3000 manual Back Panel Features, Iec Mains Connector, U.S. Domestic Ac Mains Cord, Note For Uk Only

FAQ

What is the IEC mains connector?

The IEC mains connector is a standard power connector for the amplifier that comes with an AC mains cord.

How should the U.S. domestic mains cord be connected?

The heavy-duty, 3-conductor U.S. domestic mains cord should be connected to an independent circuit capable of supporting at least 15 amps.

What are the safety precautions for speaker connections?

For sustained high-power applications, exercise care to assure the correct speaker phasing.

What is the IEC mains connector?

The IEC mains connector is a standard power connector for the amplifier that comes with an AC mains cord.

How should the U.S. domestic mains cord be connected?

The heavy-duty, 3-conductor U.S. domestic mains cord should be connected to an independent circuit capable of supporting at least 15 amps.

What are the safety precautions for speaker connections?

For sustained high-power applications, exercise care to assure the correct speaker phasing.

How should the amplifier be grounded properly?

The amplifier should always be properly grounded to prevent the risk of shock or fire hazard.