1–Product Overview
Adapter Specifications
1-4 SN0054671-00 B
Environmental SpecificationsThe environmental specifications are listed in Table1-1.
Table 1-1. Environmental Specifications
Condition Operating Non-Operating
Temperature Ranges
(for Altitude=900 m or 2952.75 ft)
10°C to 55°C a
(50°F to 131°F)
a200LFM is required to operate at this temperature.
–40°C to 65°C
(–40°C to 149°F)
Temperature Ranges
(for Altitude >900 m or 2952.75 ft)
10°C to n°C b
(50°F to n°F c)
bUse the following formulas to calculate the maximum operating temperature (in °C) for a specific
altitude. Use the first formula if the altitude is stated in meters and the second formula if the altitude
is stated in feet.
cUse the following formulas to calculate the maximum operating temperature (in °F) for a specific
altitude. Use the first formula if the altitude is stated in meters and the second formula if the altitude
is stated in feet.
–40°C to 65°C
(–40°F to 149°F)
Temperature Gradient Maximum
per 60 Min.
10°C 20°C
Humidity Percent Ranges—Non-
condensing
20% to 80%
(Max. Wet bulb temper-
ature= 29°C) d
dMaximum corrosive contaminant levels measured at =50% relative humidity; see Table 3 in
ISA-71.04-1985.
5% to 95%
(Max. Wet bulb temper-
ature= 38°C)d
Humidity Gradient Maximum
per 60 Minutes
10% 10%
Altitude Ranges—Low Limits –15.2m (–50 ft) –15.2m (–50 ft)
Altitude Ranges—High Limits 3,048m (10,000 ft) 10,668m (35,000 ft)
Airborne Contaminants—ISA-71
Level
G1d G1d