Utility/Diagnostic Functions (continued)

RS-232 Communications Procedure:

1)Connect the RS-232port of the RAVE 522aa to an unused serial port (COM port) of a PC using a normal (straight through) serial cable.

2)Open the HyperTerminal program. This program is usually started by clicking the Windows Start icon, selecting Programs, then Accessories, Communications, and finally, highlighting the Hyper Terminal folder and clicking on its icon.

3)After starting Hyper Terminal, a Connection Description window will pop-up. It will require that you name your connection. Enter a name for your new connection (example: RAVE 522aa) and click OK to continue.

4)Next, Hyper Terminal needs to know how to “talk” to the RAVE 522aa. This selection depends on which port on your PC the cable is connected to. Ignore the first three entry fields (phone number information) and go directly to the Connect using entry field and click on the down arrow for the drop-down menu selection. Select the port the RAVE 522aa is connected to and click OK to continue. The Properties window should appear next.

5)The Properties window for the selected COM port should now be active. For the Port Settings, use the following information so communication between the RAVE 522aa and the computer is in the same “language”.

Bits per Second: 9600

Data Bits: 8

Parity: none

Stop Bits: 1

Flow Control: Xon/Xoff

Once you have set the properties as outlined, click OK to continue. If all the connections and communications settings are correct, the main Hyper Terminal window will open.

6)The Hyper Terminal main window will appear next, but blank. Type the letter “h” (for help) and then the “Enter” key. This will prompt the RAVE 522aa to post its menu text. The “h” key is the Help prompt for the RAVE 522aa. A text menu will appear. This is sent by the RAVE 522aa and will detail your options and instructions for changing the address information.

From this main-menu you will need to make your menu choices and follow the instructions in the following sub-menus or screens. Although many of the instructions and tests may not pertain to a specific setup or troubleshooting situation, you may be asked to run certain tests by a QSC technical representative. The results of these tests will help to troubleshoot any problems.

The most common user item that might require settings to be changed would be the IP address information. This would be useful if the IP address was inadvertently changed to an unrecognized address and subsequently you were unable to “talk” to the RAVE 522aa over the network. This situation would require the Display Network Settings and Enter Network Setup items to be accessed for re- assigning a valid IP address.

IP ADDRESS ASSIGNMENT-

ONLY REQUIRED FOR ATTACHING TO EXISTING NETWORKS!

DO NOT CHANGE THE COMMUNICATIONS SETTINGS OF THE RAVE 522aa UNLESS CERTAIN OF YOUR ACTIONS. THE FACTORY-PROGRAMMED IP ADDRESS CAN BE ACCESSED USING THE FRONT PANEL DISPLAY MENU SYSTEM. RECORD THIS IP ADDRESS SHOULD YOU NEED TO RETURN TO THE INITIAL SETTINGS.

22