Castile & Santa Fe CE Pellet Stove
B. Clearances to Combustibles
A |
B |
C
C
Alcove Installation | Millimeters |
Minimum Alcove Height | 1092 |
Minimum Alcove Side Wall | 152 |
Minimum Alcove Width | 965 |
Maximum Alcove Depth | 914 |
I | I |
J | |
J | C |
| |
| L |
Straight Back Against Wall | Millimeters | ||
A | Back Wall to Appliance | 50 |
|
B | Side Wall to Appliance | 160 |
|
|
|
| |
Corner Installation | Millimeters |
| |
C | Walls to Appliance | 50 |
|
Installations with:
76mm to 76mm Top Vent Adapter and 76mm to 152mm Offset Adapter
C |
|
L |
|
Dimension to Corner | Millimeters |
I Flue Center Line (Santa | 217 / 264 |
Fe/ Castile) |
|
J Back of Top Vent Adapter | 232 |
WARNING
Fire Risk.
F | D |
| E |
GH
G
Comply with all minimum clearances to combustibles as specified.
Failure to comply may cause house fire.
NOTE:
• Illustrations reflect typical installations and are FOR | |
• | DESIGN PURPOSES ONLY. |
Illustrations/diagrams are not drawn to scale. | |
• | Actual installation may vary due to individual design |
Vertical Installation | Millimeters | |
D | Back Wall to Flue Pipe | 76 |
E | Side Wall to Cast Top | 152 |
F | Back Wall to Appliance | 178 |
preference. |
Corner Installation | Millimeters | |
G | Walls to Appliance | 50 |
H | Side Wall to Flue Pipe | 76 |