IC-485S/IC-485SIINSTALLATION

2-2 SWITCH FUNCTION DESCRIPTION

Refer to the location of the SW1 and SW2, please see Figure 1- 1.

IC-485S:

IC-485SI:

SW 1: Device Mode Selection

Position 1: DCE means the IC-485 is set at DCE mode and it must be connected to a DTE device.

Position 2: DTE means the IC-485 is set at DTE mode and it must be connected to a DCE device.

Position 3: Monitor means the IC-485S is set at monitor mode and it is used to monitor

-____

4

User’s Manual

INSTALLATIONIC-485S/IC-485SI

the RS-485 line signals (for IC-485S only).

SW2: Transmitting and Receiving mode selection

Position 1: (TxON, RxON) means the IC-485 is always in transmitting mode and in re- ceiving mode.(using in Point-to-Point mode)

Position 2: (TxRTS, RxRTS) means the K-485 is in transmitting mode while RTS signal is at high level and it is in receiving mode while RTS signal is at low level.(using in Multidrop mode)

Position 3: (TxRTS, RxON) means the IC-485 is always in receiving mode and it is in transmitting mode only while RTS sig- nal is at high level.(using in Multidrop mode to monitor the RS-485 line signals)

Note: DTE means Data Terminal Equipment.

DCE means Data Communication Equipment.

More detailed information, please refer to the Appendix.

User’s Manual

5

Page 5
Image 5
QVS IC-485SI user manual Switch Function Description