CGC-1e Complete Greenhouse Controller

CGC-1e Complete Greenhouse Controller

OVERVIEW

The CGC-1e Complete Greenhouse Controller from C.A.P. controls all of the main devices required in today’s modern hydroponic garden.

WORD TO THE WISE...

CGC-1e

Before attempting to operate the CGC-1e, you should at least take the time to look at the Example Connection diagram on page 2 and read the “Start- up Procedure on page 3 of this manual. To get the most out of the CGC-1e, familiarize yourself with this manual. It contains many useful hints; examples and a troubleshooting guide.

IMPORTANT STUFF TO REMEMBER

The CGC-1e is designed to operate from a 120vac, 15-amp power source. It can safely control up to 15-amps of equipment including up to 1000 watts of HID lights. If required, additional lights and larger equipment can be connected to the CGC-1e by using our HPR, MLCs or UPM “Universal Remote Power Modules”. In addition to lights, the CGC-1e also maintains the temperature and humidity by controlling your exhaust fan(s). CO2 levels can be controlled with the built-in timers, which are coordinated with your exhaust fans and function only when the lights are ON. Or you can upgrade later to PPM Part-Per- Million control by adding the PPM-1c CO2 monitor. And to complete the package, the built in Adjustable Recycling Timer is perfect for controlling your hydroponic pumps and more!

PROTECTION & SAFETY

The CGC-1e is overload protected a main 15-amp fuse. Do not exceed the maximum rating of the CGC-1e. IMPORTANT: Replace blown fuses with fuses of the same rating ONLY!

Note: A surge suppressor power strip is always recommended when operating electrical equipment such as the CGC-1e.

WARRANTY

The CGC-1e is protected by our 3-year limited warranty. All components are warranted by R & M Supply against defects in workmanship and materials under normal use for 3-years from the date of purchase. The CGC-1e is 100% maintenance-free and does not require service.

INSTALLATION / START-UP

There are a few requirements for a successful installation and start-up.

1)The CGC-1e must be mounted in a vertical position. Mounting feet are included to allow you to secure the unit to a wall.

2)The CGC-1e requires “free air movement” to maintain temperature and humidity accuracy. The top and bottom of the enclosure has ventilation slots to provide air flow through the unit however, we greatly recommended using an oscillating fan in the growing area to provide fresh air for the internal humidity sensor and provide adequate ventilation for the internal electrical components.

3) A dedicated 120 VAC, 15-amp power supply is recommended. A ground wire (3-wire outlet) must be used.

Do not use 2-wire adapters or cords to operate the CGC-1e.

4)The CGC-1e must be protected from water. Do not mount the unit where it can be exposed directly to water.

5)Read the rest of the manual!!! It has been designed to take you through step-by-step to make start-up a breeze.