SELF TEST

The self test feature is useful to verify the correct operation of the UPS and the condition of the batteries. With the UPS in the AC normal mode, press and hold the On/Off/Test Button for four beeps, then release the button. The UPS will perform a ten-second self test. During the self test, the UPS will switch to battery power and the On-Battery LED will illuminate and the audible alarm will sound. The length of the test that is automatically performed every two weeks is longer than the start-up or user invoked test. This test will run for approxi- mately fifteen-seconds to measure the battery’s capability to provide an ac- ceptable amount of runtime. If the UPS fails a self test, one of the LEDs will remain illuminated indicating the type of problem. NOTE: The UPS will auto- matically perform a self test on start-up and every two weeks.

DIP SWITCH SETTINGS

The DIP Switch setting may be changed by the user to set the desired Inverter (On-Battery) output voltage. The DIP Switch must be set to the desired Inverter (On-Battery) output voltage and then the UPS must be turned off and restarted to reconfigure the microprocessor and save the changes. The Inverter (On- Battery) output voltage setting can be either 120VAC (default) or 127VAC. Chang- ing the Inverter (On-Battery) output voltage to 127VAC, will also change the Buck setpoint from 130VAC (default) to 137VAC.

Inverter (On-Battery)output voltage

Switch

1

2

120V

(Off)

(On)

127V

(On)

(Off)

English

LOAD SHEDDING FUNCTION

The output receptacles are electrically wired into two segments to support the "Load Shedding Function". The user can control the two segments individually or both at the same time. The Load Shedding Function is controllable by the Power Monitoring Software or the SNMP card.

ALARMS

ON BATTERY

When the UPS is operating on the batteries, the On-Battery LED will illuminate and the audible alarm will sound once every ten-seconds. The alarm will stop once the UPS returns to the AC normal mode.

LOW BATTERY WARNING

The UPS will sound two beeps every five-seconds when the battery reserve runs low. This condition will continue until AC returns or the UPS shuts down from battery exhaustion.

UPS FAULT

When the UPS detects a hardware fault, the Fault LED will illuminate and the UPS will sound a constant alarm. The fault condition, in some instances, may be reset by turning the UPS off and then on.

13

Page 14
Image 14
Rackmount Solutions E1500RM1U, E1000RM1U, E700RM1U manual Alarms, Self Test

E700RM1U, E1000RM1U, E1500RM1U specifications

Rackmount Solutions has established itself as a reputable provider of high-quality server racks and components, catering to a wide range of technological needs. Among its offerings, the E1500RM1U, E1000RM1U, and E700RM1U rackmount servers stand out for their reliability, efficiency, and exceptional performance in various industries.

The E1500RM1U is designed for high-performance computing applications. It features a dual-socket architecture, accommodating powerful Intel Xeon processors, which can handle demanding workloads with ease. This model supports extensive memory configurations, with up to 1TB of RAM, making it ideal for virtualization, large databases, and data-intensive applications. The E1500RM1U also includes multiple PCIe slots for GPU or additional network interface cards, offering expanded capabilities for graphics processing or enhanced connectivity. Moreover, its advanced cooling system ensures optimal thermal management, maintaining peak performance under load.

The E1000RM1U serves as a versatile solution for small to medium enterprises. It offers a single-socket architecture, providing sufficient processing power for less demanding workloads while maximizing energy efficiency. Supporting up to 512GB of ECC RAM, the E1000RM1U is perfect for applications such as web hosting, file storage, and small databases. The server comes equipped with multiple drive bays and RAID support, ensuring data protection and redundancy. Its compact one-unit design makes it an excellent choice for environments with space constraints.

Lastly, the E700RM1U targets cost-conscious businesses seeking reliable server solutions. This model is powered by Intel processors that balance performance and affordability. It supports up to 256GB of memory, delivering adequate power for light to moderate workloads. The E700RM1U includes essential features like hot-swappable drives and basic RAID configurations, making it suitable for file and application servers or as a backup solution. Its lightweight design and simple setup process make it an appealing option for those new to rackmount systems.

In summary, Rackmount Solutions offers a range of servers such as the E1500RM1U, E1000RM1U, and E700RM1U, each designed for specific performance needs and budget considerations. With cutting-edge technologies, robust features, and efficient designs, these servers are poised to meet the demands of modern businesses, providing scalable solutions that can grow alongside evolving technological landscapes.