4. ADDITIONAL INFORMATIONS
4.1 TROUBLE SHOOTING
PROBLEM SUGGESTED ACTION
Bad picture quality after power
on
Please connect the video cable on channel one before power on.
The device will detect system automatically for PAL or NTSC.
No Video 1. Please check if the power supply is connected.
2. Please check if the wiring between monitor and quad is
correct.
Video Loss
Ex. CH1 video loss at 04:08
Please check CH1 camera is connected properly.
Continuous Alarm Please check if there is any disconnection between camera and
quad.
Different Brightness, Color and
Contrast in quad screen.
Please get into VIDEO menu to set up the video parameters of each
camera.
4.2 SPECIFICATION
Video input port 4 +1 (VCR) cameras
Video output port 1 switch & 1 quad output
Alarm input 4
Alarm output 1
Alarm duration 1 – 99 sec.
Camera Title 10 characters
Time / Date set Built-in real time clock
Dwell Time 1 – 30 sec.
RS-232 port Yes
Load impedance 75Ω
Operating environment 10~80%RH, 0oC~50oC
Power sou rce DC 12V ± 10%, 500mA
Power consumption 6W maximum
Dimension (mm) 240(W) x 45 (H) x 150 (D)
Weight 1,300g