DN1 17
Fill in the chart with the ratings imprinted on your batteries. This should help
you to determine the proper jumper settings
DN1 FINAL ASSEMBLY INSTRUCTIONS
Use scrap resistor leads to form the proper “jumper” wires to configure your
conditioner. Use the parts diagram to identify the proper holes for the jumper
wires
CHARGING CURRENT SETUP
SAFETY TIME OUT CONFIGURATION SETUP
Charging
Current
Jumpers
Used
250 mA A-C, B-D
500 mA C-D
1 A A-F, C-D, B-E
Charge
Rate
Jumper
TM1 to..
Jumper
TM2 to...
Charging
Time (Min)
C/2 H No Connection 180
C G J 90
2C No Connection J 45
4C H J 23
Setting the charge current too high can
cause the cell to explode! Consult the
battery manufacturers specifications for
proper charge current specifications.
Battery Type Number of
Cells
Charge
Capacity (A•
Hr)
Charge
Current
(mA)
Time Out
Setting
(Min.)