Mounting the hood body

 

Before attaching the hood body, tighten the two screws Vr lo-

Vr

 

cated on the hood body mounting points.

 

 

• Hook the hood body onto the screws 12a.

 

• Fully tighten support screws 12a.

 

Adjust screws Vr to level the hood body.

12a

Connections

DUCTED VERSION AIR EXHAUST SYSTEM

When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe ø 150 or 125 mm, the choice of which is left to the installer.

To install a ø 125 mm air exhaust connection, insert the re- ducer flange 9 on the hood body air outlet and the adapting ring ø120-125 10 on the reducer flange.

Fix the pipe in position using sufficient pipe clamps (not sup- plied).

Remove any activated charcoal filters.

ø 150

ø 125

10

9

RECIRCULATION VERSION AIR OUTLET

Insert the connection extension pieces laterally 14.1 in connec- tion 15.

Insert the Connector 15 into the Support bracket 7.3 and fix it with a screw.

Make sure that the outlet of the extension pieces 14.1 is hori- zontally and vertically aligned with the chimney outlets.

Connect the air outlet connection 15 to the hood body outlet

using either a flexible or rigid pipe ø 150 mm, the choice of which is left to the installer.

• Ensure that the activated charcoal filters have been inserted.

7.3

14.1

 

15

 

 

ø 150

EN

 

7

 

7

Page 7
Image 7
Rangemaster RMG2H90SS, RMG2H60SS manual Mounting the hood body, Connections, Ducted Version AIR Exhaust System