Rayburn 200SFW, 212SFW installation instructions Preparation Of Site, Cooker Position, Air Supply

Models: 200SFW 212SFW

1 8
Download 8 pages 45.75 Kb
Page 3
Image 3
PREPARATION OF SITE

IMPORTANT: LIFT OUT THE HOTPLATE AND CEMENT SEAL THE JOINT BETWEEN THE BOILER FACE AND ITS LOCATING FACE ON THE FIREBOX SIDES WITH FIRE CEMENT. RENEW ANY BRICKWORK CEMENTED JOINTS THAT MAY HAVE OPENED IN TRANSIT.

PREPARATION OF SITE

The non-combustible hearth must be solid and level and together with the walls adjacent to the cooker and chimney, conform to current Building Regulations.

The cooker and chimney flue installation should be in accordance with the relevant recommendations of BS8303, BS. 6461 Part 1 and BS. 7566 Parts 1 to 4.

Rayburn Cookmaster Plus 212SFW - The boiler installation section must also be in accordance with the byelaws of the local Water Undertaking and any relevant requirements of the Local Authority.

COOKER POSITION

When the cooker is installed in a recess it must be ‘freestanding’ and not built-in solid at the sides.

Where the cooker is to stand in a recess or against a wall which is to be tiled, in no circumstances should the tiles overlap the cooker top plate.

Ensure that any combustible material e.g. kitchen furniture is spaced away from the cooker to the recommended distances. See Fig. 1. The work surface however, may be fitted to the top plate on both sides.

NOTE: SMOKE/SMELL EMITTED DURING INITIAL USAGE

Some parts of the cooker have been coated with a light covering of protective oil, this may cause smoke/smell to be emitted, and is normal and not a fault with the appliance, it is therefore advisable to open doors and or windows to allow for ventilation. Lift the insulating lids to prevent staining the linings.

AIR SUPPLY

Rayburn Cookmaster 200SFW: There is no requirement for additional ventilation as this appliance is rated at less than 5kW. Should another appliance be used in the property and the total heat output is greater than 5 kW, additional ventilation must be provided in accordance with the Building Regulations.

Rayburn Cookmaster Plus 212SFW: Provision must be made for additional ventilation. A permanent unobstructed air vent having a minimum effective area of 5.5 cm2 must communicate to outside air or an adjacent room which in turn has a permanent vent of at least the same size to outside air.

If a flue draught stabiliser is fitted in the flue this vent size must be increased to a minimum 23.5 cm2. If his appliance us used with an additional appliance of a similar type then the air supply must be adequate for both appliances in accordance with the Building Regulations.

Any air inlet grilles must be positioned so that they are not liable to blockage.

It is not permissible to use an air extraction device in the same room as the appliance, unless additional ventilation is provided to prevent any adverse effect on the flue.

Effect of Extractor Fan

Avoid if possible the installation of an extractor fan in the same room as the appliance or the room where the permanent air vent is located.

Compensating extra air inlets must be introduced equivalent to the capacity of the fan wheel when fitted.

3