THE CHIMNEY
The minimum chimney draught requirement for the 200SFW at nominal total heat output is 2.5 Pa.
The minimum chimney draught requirement for the 212SFW at nominal total heat output is 12 Pa.
The mean flue gas temperature of the Rayburn 200SFW directly downstream of the flue spigot at nominal heat output is 131ºC.
The mean flue gas temperature of the Rayburn 212SFW directly downstream of the flue spigot at nominal heat output is 210ºC.
The appliance is not suitable for installation in a shared flue system
Checking Existing Chimney
The internal and external location of the chimney should be checked before the appliance is installed and rectification made where necessary to prevent leakage or porosity. The soundness of the chimney which should have a minimum flue dimension of 150mm can be confirmed by smoke testing.
Advice on the test method can be obtained from HETAS Ltd.
When repairing or
The chimney MUST be swept before installation.
Erecting New Chimney
The flue through the chimney should be formed with
Ensure the chimney liners are free of projecting internal building jointing composition before the appliance is installed.
Factory-Made Insulated Chimneys
It is recommended the chimney be ceramic lined and comply with BS. 4543: Part 2.
The minimum diameter for a straight chimney is 150mm and there should be not more than two bends of 45º from vertical.
Fig. 2
Fig. 3
Fig. 4
DESN 510181 C
DESN 510182 C
DESN 510183 C
4