Job: |
|
|
|
| Raytherm® - Type WH | |||
Engineer: |
|
|
|
|
| Water Heaters | ||
|
|
|
|
| ||||
Contractor: |
|
|
|
| Commercial | |||
|
|
|
| |||||
Prepared By: |
|
|
| Models 2100 - 4001 | ||||
Model: |
| Indoor Date: | ||||||
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
EFFICIENT
82% thermal efficiency – highest of any atmospheric water heater available today
THERMAL SHOCK PROOF
Maximum operating temperature: 210°F
LIGHTWEIGHT
A floor load of 70 lbs./sq. ft. or less
HIGH RECOVERY
Cuts fuel costs substantially because the standby and radiation losses associated with
LOW WATER OPERATING TEMPERATURE |
|
|
| INDOOR | ||||||||
| Operates with water temperature as low as 105°F |
|
|
|
| |||||||
| without condensing |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
Heat Exchanger | Gas Control Train | Water Heater Controller | ||||||||||
ASME Inspected and Stamped | Manual Main Gas | Required on Model WH2 only | ||||||||||
| 160 PSIG | Main Gas Pressure Regulator |
| Modulating Controller | ||||||||
| National Board Approved | Redundant Safety |
|
|
| |||||||
| Headers | | Control Valve |
|
|
| By Others | |||||
| Bronze – Standard | | Firing Mode | Temperature Controllers | ||||||||
|
| On/Off (WH1) | ||||||||||
| Fin Tubing |
|
| |||||||||
| Copper – Standard |
| Motorized Modulation (WH2) |
|
|
| ||||||
| Cupro Nickel – Option | | Fuel |
| ||||||||
ASME Steel Tube Sheet |
| Natural Gas |
|
|
| Loose | ||||||
| Silicone |
| Propane Gas |
| Electronic Sequencer, | |||||||
125 PSIG ASME Pressure Relief Valve | Design Certified ANSI Z21.10.3 |
|
|
| ||||||||
Temperature and Pressure Gauge | Construction |
| Electronic Sequencer, | |||||||||
| Water Connections |
|
|
| ||||||||
| Left Hand – Standard | | Front Controls | Additional Safety Controls | ||||||||
| Right Hand – Option | | Stainless Steel Burners | |||||||||
| | Baked Enamel Paint |
| Low Water | ||||||||
|
| |
| High Limit Control, Auto Reset, | ||||||||
Controls | Draft Inducer – Optional |
|
|
| 180°F | |||||||
120V, 60Hz, 1 Ph Power Supply |
| Motorized Draft Inducer – |
| Low Gas Pressure Switch, | ||||||||
| 120/24V Transformer |
| Indoor – Option |
|
|
| Manual | |||||
| 100% Pilot |
|
|
|
|
|
|
|
| High Gas Pressure Switch, | ||
Electronic, Intermittent Ignition (IID) Pilot |
|
|
|
|
|
|
|
|
|
| Manual | |
High Limit Control, Manual Reset – 200°F |
|
|
|
|
|
|
|
|
|
|
| |
High Limit Control, Auto Reset – 200°F |
|
|
|
|
|
|
|
|
|
|
| |
| Models |
|
|
|
|
|
|
| Regulatory Agency Requirements | |||
|
|
|
|
|
|
|
| |||||
| On/Off Switch |
|
|
|
|
|
|
| ||||
| Flow Switch |
|
|
|
|
|
|
|
|
| ||
Economaster II Pump Time Delay |
|
|
|
|
|
|
|
|
|
|
|