SNC 5100

SCSI 1-4

For each SCSI channel, the LED will be OFF when no devices have been detected on the port. It will be ON when a target has been found on the channel. It will flash when there is activity on the channel. The LED will return to the OFF state if the channel is reset.

PWR

The PWR (Power) LED will be ON when the SNC 5100 has power. It will flash if the on-board power sensors determine that any of the required supply voltages are out of range.

RDY

The RDY (Ready) LED indicates status of Ready. Normally the RDY LED flashes when the SNC 5100 has finished booting. If the RDY LED remains ON or OFF for more than a few seconds, it means there is a problem.

The RDY LED will flash rapidly, four times per second, when the SNC 5100 is running in diagnostic mode.

ERR

The ERR (Error) LED indicates that an error condition exists. This may indicate such errors as over-temperature conditions, fan stalled or other internally detected error conditions. See “POST Error Codes” on page 197.