SNC 5100

Step 4. If obstructions are found, remove them and permit the SNC 5100 to cool.

Step 5. If temperatures stabilize, exit this MAP.

Step 6. If no obstructions are found, or temperatures do not stabilize, check the SNC 5100’s Air Outlet for obstructions.

Step 7. If obstructions are found, remove them and permit the SNC 5100 to cool.

Step 8. If temperatures stabilize, exit this MAP.

Step 9. If no obstructions are found, or temperatures do not stabilize, replace the unit.

Proceed to “Before Removing or Replacing the Unit” on page 82.

Continue through “Replacing the SNC 5100” on page 84.

Fan Speed is in Warning or Alarm Range

If you were directed to this MAP because of Trap Event Code 67, indicating that the Fan is in Warning Range--replace the SNC 5100 at the next scheduled maintenance.

If you were directed to this MAP because of Trap Event Code 68, indicating that the Fan is in Alarm Range, Proceed to “Before Removing or Replacing the Unit” on page 82.

Continue through “Replacing the SNC 5100” on page 84.

Power MAP

Perform these steps if:

All LEDs are off

The SNC 5100 generates Trap Event Codes 59 or 60, indicating that the Power is running in the Warning or Alarm Range. A string accompanying a Trap Event will indicate which power supply is specifically involved.

Health Check generates a Trap Event Code 113, indicating that Power is running in Warning or Alarm Range