SNC 5100

Step 7. From the Service Terminal, enter the showBox command.

For more information, see the "showBox" command on page 194.

Step 8. Verify that the SNC 5100 accurately displays the channel information.

If the showBox display is accurate, go to step 9.

If not, go to “Start MAP” on page 42.

Step 9. Proceed to "Fibre Channel Tests"

Fibre Channel Tests

For further information about the procedures and commands used in this section, see “Connecting to the Service Port” on page 95 and “Diagnostic Command Reference” on page 187.

Test Fibre Channel Port 1

Step 1.

Attach the Fibre Channel loop back plug to the GBIC in FC 1.

Step 2.

From the service terminal, enter the fcSlotTest 1 command.

 

For more information, see the "fcSlotTest [x]" command on

 

page 192.

Step 3.

If the test passes, remove the loop back plug and go to "Test Fibre

 

Channel Port 2".

 

If the test does not pass, go to “Start MAP” on page 42.

Test Fibre Channel Port 2

Step 1.

Attach the Fibre Channel loop back plug to the GBIC in FC 2.

Step 2.

From the service terminal, enter the fcSlotTest 2 command.

 

For more information, see the "fcSlotTest [x]" command on

 

page 192.

Final Diagnostic Tests

85

6-00020-02

Page 93
Image 93
ADIC SNC 5100, Scalar 1000 manual Fibre Channel Tests, Test Fibre Channel Port