SNC 5100

SN60023 >

If SFM is already active, the following is displayed.

SN60023 > sfmActiveSet SFM: Already Active value = 21 = 0x15 SN60023 >

sfmConnectionSet [hostindex],host connection string

The sfmConnectionSet command sets the host connection information for the host at the specified connection index. The connection may be a device name, port address, etc. The following example shows setting the host connection information. Existing hostindex values can be determined by looking at the “Id” column in the output of the sfmShow -1command.

SN60023 > sfmConnectionSet 1,"ScsiPort2 [0:0:0] (QLA2100)" value = 0 = 0x0

SN60023 >

sfmFeatureEnable license key string

The sfmFeatureEnable command enables the SFM feature. Each license key is unique for each Pathlight 5000SNC 5100 serial number. If the feature is factory-enabled you can specify “enable” rather than an actual license key.

sfmHostShow [hostIndex]

The sfmHostShow command displays all known Scalar Firewall Manager information for the specified host connection index. The LUN access map is displayed as 16 rows of 16 bytes, one byte for each LUN.

hostIndex is the Id obtained from the sfmShow command.

00 in the LUN Access map indicates the host has no access to the LUN. 01 in the LUN Access map indicates the host has access to the LUN.

The following command example shows SFM information for host Id 1.

SN60023 > sfmHostShow 1

Host(1):

State = 0, Type = 1, Flags = 0x00000000, Online

WWN: 200000e0:8b0057d8

166 Commands

6-00020-02

Page 174
Image 174
ADIC Scalar 1000 If SFM is already active, the following is displayed, SfmConnectionSet hostindex,host connection string