SNC 5100

Step 1. Inform the system administrator that it is necessary to replace the Fibre Channel device connected to the SNC 5100 to resolve the Fibre Channel errors.

Step 2. Repeat this MAP, beginning with the section “Verify Fibre Channel Connections” on page 61, after replacing the external component.

MAP for the SNC 5100

Perform these steps if:

RDY LED not blinking once per second after power has been on for one minute

The SNC 5100 is not responding

SNC 5100 processor memory fault detected

SNC 5100 PCI bus parity error detected

SNC 5100 PCI interface error detected

The ADIC Management Console Server could not verify the connection to the SNC 5100

Observe Operational LED Behavior

When the SNC 5100 is first powered on, the front-panel’s LEDs flash a variety of patterns as it performs the Power On Self Test (POST) and then starts booting.

For more information, see “POST Error Codes” on page 197.

Within one minute, the SNC 5100 should have booted successfully and the Ready LED should be blinking once per second.

If the Ready LED is not blinking as expected, go to “Start MAP” on page 42.

Temperature MAP

Perform these steps if:

The SNC 5100 generates Trap Event Codes 62, 64, or 67 (Inlet Air, Outlet Air, I/O Processor, or Fan have entered a Warning Range)

66 MAP for the SNC 5100

6-00020-02

Page 74
Image 74
ADIC Scalar 1000, SNC 5100 manual MAP for the SNC, Temperature MAP, Observe Operational LED Behavior