SNC 5100

The Ethernet loop back plug, Fibre Channel loop back plug, and SCSI cable provided in the Service Tool Kit are required for the corresponding loop back test.

Caution

You must disconnect the FC and SCSI cables from the SNC 5100. If you do not, the data on the attached tape devices will become corrupted.

elTest

elTest is the Ethernet loop back test. The SNC 5100 must be in diagnostic mode to use this command and a loop back plug must be installed on the Ethernet port.

diagmode > elTest

==== Testing Ethernet ====

Init complete. Ethernet OK value = 0 = 0x0

The test issues a series of loop back tests. Test data is transferred and verified. A good test ends with Ethernet OK.

If errors are detected, the test displays the number of bad test iterations as shown below. If your test was not succesful, return to the MAP that sent you here.

diagmode > elTest

==== Testing Ethernet ====

Init complete. Ethernet timeout error Ethernet timeout error Ethernet timeout error Ethernet timeout error Ethernet timeout error Ethernet timeout error

Ethernet test reported 6 errors out of 12 iterations value = 6 = 0x6

fcSlotTest [x]

The SNC 5100 must be in diagnostic mode to use this command and a loop back plug must be connected to the GBIC.

192 Diagnostic Commands

6-00020-02

Page 200
Image 200
ADIC Scalar 1000, SNC 5100 manual ElTest, FcSlotTest