SNC 5100

network. Interpreting these statistics requires detailed knowledge of Internet networking protocols. This information may be useful to the LAN administrator.

SN60023 > icmpstatShow ICMP:

0 call to icmp_error

0 error not generated because old message was icmp

0 message with bad code fields

0 message < minimum length

0 bad checksum

0 message with bad length Input histogram:

destination unreachable: 1

0 message response generated value = 30 = 0x1e

SN60023 >

ifShow

The ifShow command is used to show the Ethernet port parameters and status as shown below. The SNC 5100 will show two devices. ibmEmac is the Ethernet port. lo is the local loopback port.

SN600752 > ifShow ibmEmac (unit number 0):

Flags: (0x8063) UP BROADCAST MULTICAST ARP RUNNING

Type: ETHERNET_CSMACD

Internet address: 172.16.76.211

Broadcast address: 172.16.255.255 Netmask 0xffff0000 Subnetmask 0xffff0000 Ethernet address is 00:60:45:17:02:f0 Metric is 0

Maximum Transfer Unit size is 1500

114192 packets received; 364 packets sent

114023 multicast packets received

116 multicast packets sent

0 input errors; 0 output errors

0 collisions; 0 dropped lo (unit number 0):

Flags: (0x8069) UP LOOPBACK MULTICAST ARP RUNNING

Type: SOFTWARE_LOOPBACK

Internet address: 127.0.0.1

Netmask 0xff000000 Subnetmask 0xff000000

Commands 139

6-00020-02

Page 147
Image 147