SNC 5100

Air Outlet Temperature

Nominal

51 C

IO Processor Temperature Warning 31 C

Input Power: ± 5 Volts

Nominal

5.2

V

Input Power: ± 12

Volts

Nominal

12 V

 

Local Power ± 2.5

Volts

Nominal

3.3

V

Local Power ± 3.3

Volts

Nominal

3.3

V

Local

Power ± 3.3 Volts Aux Nominal 3.29 V

All

Power

Nominal

All

Temp

Nominal

Sample Count

20

value

= 1 = 0x1

envMonRangeShow

The envMonRangeShow command specifies operational ranges for the SNC 5100's environmental channels. It displays ranges of values associated with the Nominal, Warning, and Alarm states for voltage, temperature, and fan/blower operation according to the channels defined in the envMonShow command:

SN600012 > envMonRangeShow

Air Inlet Temp (C):

Nominal: 5 to 45

Warning: 4 <= N < 5 or 45 < N <= 50

Alarm: N < 4 or N > 50

Air Outlet Temp (C):

Nominal: 5 to 50

Warning: 4 <= N < 5 or 50 < N <= 55

Alarm: N < 4 or N > 55

IO Processor Temp (C):

Nominal: 5 to 80

Warning: 4 <= N < 5 or 80 < N <= 108

Alarm: N < 4 or N > 108

Commands 119

6-00020-02

Page 127
Image 127
ADIC SNC 5100, Scalar 1000 manual EnvMonRangeShow