SNC 5100

Table 3: Installation Checklist

Step

Actions

Comments and References

 

 

 

15

Verify all target devices are available to

Use appropriate host system utilities for

 

the host system.

disk and tape. See Table 4.

 

 

If all devices are NOT available, reboot

 

 

host system(s) and check again.

 

 

If problem persists, go to “Start MAP” on

 

 

page 42.

 

 

 

Host Utility Software

Table 4: Host Utility Software

Platform

Host Utility Software Name

Host Utility Software Function

 

 

 

Windows

Disk Administrator

show attached devices

 

SCSI Adapter control panel applet

show installed scsi adapters

 

Tape Devices control panel applet

show installed tape device drivers

 

 

 

Solaris

st.conf1

specify LUNs to be scanned for tape

 

 

devices1

 

reboot -- -r

rescan

 

ls/dev/rmt

show mapped tape devices

 

 

 

AIX

lsdev -Cc tape

list all tape devices

 

lsdev -Cc adapter

list all adapters

 

rmdev - dl fcs[n] -R

remove devices no longer present

 

where [n] is the

 

 

 

number of the device

reconfigure

 

cfgmgr

 

 

 

 

 

HP-UX

ioscan -C disk

scan for devices

 

 

 

NOTE:

 

 

1Because systems vary it is generally not possible to just replace the existing sd.conf or st.conf with a new one. Therefore you will have to add multiple LUN entries for SCSI ID 0 to sd.conf. After the existing line:

name=”st” class=”scsi” target=0 lun=0; add lines of the form:

name=”st” class=”scsi” target=0 lun=1;

until you have as many lines as are needed, one line per storage device or volume. Be sure to increase the LUN number appropriately.

Installation Procedure

23

6-00020-02

Page 31
Image 31
ADIC SNC 5100, Scalar 1000 manual Host Utility Software