SNC 5100

writes to the flash file system will be lost. This operation is not typically used. The reboot command should be used to gracefully shutdown and restart the SNC 5100.

SN60023 > reset

restartScsi [channel]

The restartScsi command restarts the specified SCSI Channel without issuing a bus reset.

SN60023 > restartScsi 1 value = 0 = 0x0 SN60023>

ridtag [value]

The ridtag command is used to change the replacement identifier (RID) tag for the SNC 5100 after it has been replaced by the service representative. This should be the final step after replacing and verifying that the replacement unit is performing satisfactorily.

The sysVpdShow command will display the RID tag. Before replacing the SNC 5100, you must determine the existing RID tag, if there is one, or the original serial number if no replacement has been made.

If the ridtag command is entered with a string, that string becomes the RID tag recorded for the unit.

SN60023 > ridtag “12D345677”

*** value = 0 = 0x0

If a string is not entered, the existing RID tag is displayed.

SN60023 > ridtag RID Tag = 12D345677 value = 0 = 0x0 SN60023 >

On original equipment, the RID tag will be blank.

152 Commands

6-00020-02

Page 160
Image 160
ADIC Scalar 1000, SNC 5100 manual RestartScsi channel, Ridtag value, On original equipment, the RID tag will be blank